Model CY-SZ09 -Integrated Water Quality Monitoring Station

SHARE

Measurement principle: modular design to meet different on-site monitoring requirements; small size (1.5m2), less floor space, complete configuration, good mobility; Outdoor installation, no need of civil engineering; modular outdoor chassis design and modular analysis unit, with case air conditioning, strong environmental adaptability, easy to expand; high integration, system process introduction, easy maintenance and operation of equipment; equipped with industrial computer system, in accordance with the technical specifications for automatic surface water monitoring; Compatible with multiple communication modes.

Most popular related searches
  • CODcr water quality on-line automatic monitor: potassium dichromate spectrophotometry;
  • permanganate water quality on-line automatic monitor: potassium permanganate oxidation spectrophotometry;
  • online automatic monitoring instrument for ammonia nitrogen water quality: salicylic acid spectrophotometry;
  • online automatic monitoring instrument for total phosphorus water quality: ammonium molybdate spectrophotometry;
  • total nitrogen water quality online automatic monitoring instrument: basic potassium persulfate oxidation ultraviolet spectrophotometry;
  • Water quality five parameters: electrode method.
  • Monitoring factor CODcr permanganate ammonia nitrogen total phosphorus total nitrogen
  • The measuring range is 10~5000mg/L 0~20mg/L 0~300mg/L 0~50mg/L 0~50mg/L
  • Accuracy ±5% ±5% ±5% ±10% ±10%
  • Repeatability < 5% < 5% < 2% ±10% ±10%
  • The measurement cycle was < 30min < 35min < 25min < 30min < 35min
  • Sampling cycle time interval (0-9999min) and 24H hourly time measurement mode
  • Calibration period can be automatically calibrated interval
  • Output signals: RS232, RS485, GPRS (customizable)
  • Recommended temperature for environmental requirements: 5-35?, humidity ≤85% (no condensation)
  • Power supply AC220V±10%, 50Hz
  • Abnormal alarm of other instruments;Power failure data is saved automatically;60,000-color TFT touch screen display and command input;
  • Abnormal reset and automatic reset after power failure CODcr
  • 10 ~ 5000 mg/L
  • Monitoring factor measurement principle range repeatability relative error
  • PH electrode method: 0~14.00pH ≤2% ≤±0.05
  • Dissolved oxygen fluorescence method: 0~20mg/L ≤2% ≤±1%
  • Conductivity electrode method: 0~500mS/cm ≤2% ≤±1%
  • Turbidity infrared method: 0~4000NTU ≤2% ≤±1%
  • Temperature thermistor 0~80? ≤2% ±0.3?