Pavone Sistemi S.R.L.
  1. Companies
  2. Pavone Sistemi S.R.L.
  3. Products
  4. Model MCT 1302 - Weight Indicators

Model MCT 1302 -Weight Indicators

SHARE

The MCT 1302 touch screen weight indicator is ideal for all types of weighing, in particular for static weighing and loading / unloading and multi-component dosing. It is easy to install and use and can be customized as needed. MCT 1302 has a multilingual menu, a touch screen keyboard, removable screw terminal blocks (3.81mm pitch), internal data memory of 64 Kbytes expandable up to 1024 Kbytes and simultaneous availability of Fieldbus and analogue output. The Software Optimation is given for free. This Software allows you to run certain activities such as calibration or monitoring directly from your computer. The Optimation software is provided by Pavone Systems and guarantees a perfect instrument run.

Most popular related searches

Legal for Trade: certification available on request

Measuring range: -3.9 ÷ +3.9 mV/V

Input sensitivity: 0.02 µV/count

Full scale non-Linearity: <0.01 % full scale

Gain drift: < 0.001% FS/°C

Display: graphic LCD (240x128 pixel)

A/D Converter: 24 bit; internal resolution up to 16.000.000

Trasducer input voltage: 5 Vdc (max 8 cells -350 Ohm)

Frequency signal acquisition: 12 ÷ 1000 Hz

Visible resolution (in divisions): 999999

Divisions value (adjustable): x1, x2, x5, x10, x20, x50; max 4 decimals

Temperature range: -10 ÷ + 50°C (humidity max 85% no condensation)

Storage temperature: -20 ÷ +70°C

Filter: 0.1 ÷ 250 Hz

Logic output: 6 opto-isolated; max 24 Vdc/100mA each

Logic input: 6 optically isolated 24 Vdc PNP (external power supply)

Additional I/O: up to 4 external modules with 4 in/8-out each (16 in/32 out, total) by independent RS485

Serial port: 1 USB device + 1 RS232C + 1 RS485/Fieldbus

Power supply: 18 ÷ 30 Vdc - Power consumption 5 W

Microcontroller: ARM Cortex M0 + 32 bit 256KB Flash reprogrammable onboard from USB

Data storage: 64 Kbytes expandable up to 1024 Kbytes

Regulatory compliance: EN61000-6-2, EN61000-6-3 for EMC; EN61010-1 for Electrical Safety, EN45501 for metrology

Drilling template: 138 x 82 mm (L x H)

Dimensions: 150x95x26mm (LxWxH) including terminal blocks; 150x95x56mm (WxHxD) with fieldbus options

Fieldbus: Ethernet 10/100 con protocolli TCP, MODUBUS/TCP, UDP, IP, ICMP, ARP; Profinet; Ethernet/IP; Ethercat