Model Q46H/65 -Chlorine Dioxide Monitors
Chlorine Dioxide is a powerful oxidizing agent used for disinfection of potable water, cooling towers, and food wash water. It is also widely used for the bleaching of pulp in paper mills. As a disinfectant, ClO2 has advantages over chlorine in that it does not react with ammonia and many organic compounds while proving more effective at controlling bacteria, spores, viruses, and cysts. It is particularly well suited for removing biofilms from the inside of piping systems.
ATI`s Model Q46H/65 Chlorine Dioxide Monitor provides an economical and reliable measurement system for water quality monitoring and controlling ClO2 treatment systems. With a variety of outputs including 4-20 mA analog, PID control and digital communications, the Q46H/65 is adaptable to any ClO2 application.
Two versions of the sensor are available, a sensor intended for installation in a flowcell and a sensor intended for submersion applications. Requiring minimal maintenance, sensors are easy to use and easy to maintain. An integral RTD provides temperature compensation and allows temperature to be displayed and transmitted from the monitor.
SENSOR STABILIZATION
Chlorine Dioxide sensors require 2 to 4 hours of stabilization time when first installed or after membrane change. ATI offers a battery powered “polarizer” that can be used to stabilize a spare sensor so it is ready to run within a few minutes of installation. Polarizers simply plug into the sensor connector and require no adjustments.
pH Input Option
Enables monitor to measure both chlorine dioxide and pH. One analog output may be assigned to the pH measurement, allowing remote monitoring and recording of both variables.
Programmable range options from 0-200 PPB up to 0-200 PPM provide maximum application flexibility.
AC or DC Power Options
Power options include universal 100-240 VAC or 12-24 VDC.
Two isolated 4-20 mA outputs are standard, with an option for a third output if required. Default setting provides analog outputs for ClO2 and temperature.
PID Output
Standard PID control function assignable to one analog output.
Available for either Profibus-DP, Modbus-RTU, or Ethernet-IP.
Three SPDT relays are standard, with relay functions programmable for alarm, control, or trouble indication. Three additional low power relays available as an option.
Flexible Mounting
NEMA 4X (IP-66) enclosure is suitable for wall, pipe, or panel mounting.