SGB GmbH
Model VL 34 -Vacuum Leak Detector
FromSGB GmbH
Vacuum leak detection system to monitor single walled tanks equipped with a lining. A suction line to the deepest point of the interstitial space is required.
Most popular related searches
vacuum leak detection
double wall tank
leak detection system
flash point
leak detection
tank leak detection system
leak detection monitoring
leaking tank
vacuum tank
leak monitoring
New, electronic operating, with convincing advantages:
- Long lasting LED’s for the indicaition of the operating modus.
- Simple installation
- electrical connection from the top or bottom.
- real“ threeway cocks in suction- and measureing line for the perfect and quick function control. Extremly efficient with larger interstitial spaces.
- And more we are pleased to explain
Additional terminals for the connection of external signals and potential free (dry) relay contacts for alarm transmitting are standard.
Type with alarmpressure in mbar:
- VL 34
Alarm underpressure:
- > 34 mbar
Operating pressure:
- < 90 mbar
Tanks:
- single walled tanks with a lining, e.g. DIN 6608, 6616, 6625
- double walled tanks with a suction line to the bottom of the interstice, e.g. DIN 6618/2,
Liquids:
- liquids with a flash-point above > 55°C
- e.g. heating oil, Diesel, engine oil
Approvals:
- Z - 65.22 - 389