Model Zentracert -High Pressure Steam Sterilizer
A high pressure steam sterilizer for the sterilization of firm and porous goods at 121°C and 134°C according to EN 285 with capacities from 2 to 12 sterilization units (2-12 StU). The ZentraCERT is the steam sterilizer for the central sterilization department in hospitals or laboratories with an ergonomically designed loading level of 85 cm. A wide range of types, high performance process technology and equipment as well as intelligent accessories guarantee optimum safety and reliability.
LAUTENSCHLÄGER Touch-Screen - easily operated with its interactive graphical operating panel. Providing exactly the information which is needed ... language switching available on demand.
Our contribution to economy and ecology - the innovative cooling water recycle system reduces the fresh water demand by several hundred litres per cycle ... in combination with a closed loop cold water supply no more precious drinking water is required for cooling purposes.
Preventive maintenance only once a year - low-wear components, durable and accurate instrumentation and a high-volume tube condenser permit long service intervals and lowest maintenance costs ... even in operation with nonsoftened cooling water.
Not every steam sterilizer is noisy - highly efficient motor-driven vacuum pumps and intelligent process technology quiet down the ZentraCERT - only the residual running time display indicates that the sterilizer is in operation.
The patented LAUTENSCHLÄGER door seal system - the inflatable door seal is maintenance-free for several thousand cycles. The design of this system guarantees 100% leak tightness during the whole wear lifespan.
Integrierte Batch control and Bowie-Dick test - the patented Lautenschläger steam analyzer (DMA) detects non-condensable gases in the sterilizer chamber during the critical process steps. With its self-monitoring design the DMA complies with the requirements for a failure warning system and for a Bowie-Dick test system. Individually calibrated for each sterilizer it reaches highest accuracy and reproducability.
Modern sterilization processes - LAUTENSCHLÄGER sterilization cycles with their highly efficient air removal phase minimize the risks caused by non-condensable gases ... even without thermal feed water degasification. A technology which makes the daily vaccum test unnecessary.
Intelligent accessories in a flexible overall concept - the ZentraCERT transport system is easy to handle, comfortable and offers a robust mechanical design - a set of transport carts, loading carts and loading cart return locks accurately adapted to this sterilizer type.
Cycle documentation and surgical instruments tracking - the standard is a text and graphic printer. Or do you prefer an integrated software solution? The Lautenschläger data interface supports the connection of various software Systems.
The Lautenschläger steam analyzer (DMA) detects steam penetration failures caused by leakages, insufficient air removal and non-condensable gases entering the chamber together with the steam. Developed for batch and cycle control and as an integrated electronic Bowie-Dick Test to assure highest sterlization safety and optimum economic efficiency.
Failure warning system "DMA FW"
The DMA analyzes the composition of the chamber atmosphere and works as a failure warning system for cycle control purposes. It is usable as a process challenge device (PCD) acc. to EN ISO 17665 and it meets the requirements of an Air Detector acc. to EN 285. Individually calibrated for each sterilizer, the DMA reaches excellent accuracy and reproducibility - the reliable, user-friendly and cost-efficient alternative to a classic chemical indicator system. Additional cycle control systems are no longer necessary.
Steam penetration test "DMA BD"
The module BD upgrades the DMA to fulfil the demands of an alternative Bowie-Dick Test acc. to EN ISO 11140-4. With this module integrated in your Lautenschläger sterilizer, the daily Bowie-Dick Test no longer requires the standard test pack or any other alternative indicator system.
Easy handling and fully automatic documentation - as soon as you start a test or a production cycle the sterilizer automatically starts the corresponding measuring module. The system evaluates the measuring and prints the results on the cycle documentation protocol - either on the local printer or in combination with an integrated instruments tracking software solution.
Precise evaluation without risk of misinterpretation - the DMA produces clear and unequivocal measuring results: passed or failed - without any subjective interpretation or vague measurig results.
Highly accurate sterilization control with early warning system - alarm limits are individually adjusted to the sterilizer type and chamber size. Together with its highly precise measuring system and its outstanding reproducibility the DMA is able to detect lowest concentrations of non-condensable gases - far below concentrations which would cause a Bowie-Dick test failure. This enables the DMA to work as an early warning system and to significantly reduce unscheduled sterilizer shut-down periods.
A measuring device for the whole sterilizer lifetime - the DMA is designed to work with your sterilizer over its whole lifespan. DMA inspection and re-calibration are part of the yearly sterilizer maintenance service.
Time and cost advantage - no consumables, lowest possible time and effort for the measuring itself and for the evaluation, documentation and archiving of the results - the DMA is the cost-efficient solution for an integrated cycle control system.