Morningtest - Model MT -Temperature Test Chambers
Temperature test chambers focus on the required temperature simulation test from 4 optional low temperature -70 °C; -60°C; -40°C; -20°C to high temperature 180 °C.
Note:
- Chamber working room size could customize.
- If test specimens have active load during test, please inform us.
- This is temperature only model, if need make humidity test, please refer to humidity chambers.
Temperature test chambers focus on the required temperature simulation test from 4 optional low temperature -70 °C; -60°C; -40°C; -20°C to high temperature 180 °C.
Chambers with Single-stage Refrigeration systems are capable of achieving workspace temperatures down to -20°C. This is fine for many commercial and industrial tests that require low temperatures of typically 0°C, -10°C or -20°C. A single-stage system uses one compressor to directly cool the workspace.
Chambers with Cascade Refrigeration systems are capable of achieving workspace temperatures down to -40°C~-70°C depending on model. This is required for many ruggedized industrial, automotive and military test procedures that require low temperatures of typically -40°C, -55°C or -65°C. A cascade system uses two interdependent compressors.
- Interior stainless steel plate (sus#304)
- Baked panel and durable blue powder coated exterior steel plate
- High density polyurethane froth insulation or fiberglass insulation
- Welded structural base frame with removable service panels
- Dual silicone one-piece door gaskets with vulcanized corners
- Multilayer tempered heated viewing window; Anti-condensation & frost free
- One leak-proof 50mm (2 ") access port with plug on the left
- 4 heavy duty casters
- Fin heat disperse-stainless steel heater
- PID controlled-stainless steel humidifier
- 2 levels shelves, stainless steel
- Temperature measuring with PT100 in air outlet
- Anti-explosive interior lamps
- AC Power Cord
- Fast recovery fuses
- High pressure protect
- Phase reversal protect
- Circuit breaker system
- System fault status indicators
- All wiring color coded and labeled for troubleshooting
- High temperature failsafe limit
- Dupont R-404A [No Fluorine] Refrigerant
- Hermetic-single/cascade compressor
- Air cooled type (Fins with fan) condenser
- Oil separator
- High efficiency plate heat exchanger
- Inherent compressor overload protection
- Japanese Unique 7" color touch-screen controller
- Self prompting operation with 100 programmable segments.
- 600 days’ historical date
- Real-time and historical curve record
- Ethernet Connection
- USB-Connection to save measuring data on USB Stick
- Online software to connect the PC with the controller to operate from PC
- Calibration report for temperature humidity values from manufacturer
- Additional cable access ports Ø 50 mm, 100 mm and 150 mm
- Additional shelves
- Glove ports to move the test specimen without opening the door
- Chart recorders
- Microprocessor (digital indicator) controller
- 220, 415,440 or 480 Volts power input optional (depend on requirement)
- Boost cooling system, LN2 or CO2 (enable faster cooling rate and product temperature change rates in an environmental chamber)
- Additional Pt 100 for temperature measuring on test specimen
- Additional temperature protection for test specimen
- Smartphone or tablet pc WIFI monitoring
- Variable air speed in the test space
- Water cooled condensers with coil pipe available
- Calibration certificate for temperature humidity values from 3rd measurement institution.
- RS-232/RS-485 data interface