ProMinent GmbH
  1. Companies
  2. ProMinent GmbH
  3. Products
  4. ProMinent - Model Sigma/ 2 (Basic Type) ...

ProMinentModel Sigma/ 2 (Basic Type) -Motor-Driven Metering Pump

SHARE

Capacity range 50 – 420 l/h, 16 – 4 bar. Robust motor-driven metering pumps like the Sigma/ 2 Basic guarantee excellent process reliability with their patented multi-layer safety diaphragm. The diaphragm metering pump offers a number of power end versions, also suitable for use in areas at risk from explosion.

Most popular related searches

The robust pump for safe and reliable use.

The Sigma/ 2 diaphragm metering pump, together with pumps of type Sigma/ 1 and Sigma/ 3, represents an integrated product range. They cover the capacity range from 17 to 1,030 l/h, with a consistent operating concept, control concept and spare parts management. A wide range of power end versions is available, including some for use in ATEX areas.

Excellent process safety and reliability:

  • In the event of an accident, the feed chemical does not escape to the outside nor into the pump`s power end, thanks to the patented multi-layer safety diaphragm with optical (optionally electric) signalling
  • Integrated relief valve protects the pump against overloading
  • Reliable operation by bleed option during the suction process

Flexible adaptation to the process:

  • The Sigma product range is available as standard in the 'Physiologically safe in respect of wetted materials' 'F' design.
  • Metering pumps with electro-polished stainless steel metering head enable them to be used in hygienically challenging applications
  • Wide range of power end versions, also for use in areas at risk from explosion, and different flange designs for the use of customised motors
  • Stroke length: 5 mm,
  • Stroke length adjustment range: 0 – 100%
  • Stroke length adjustment: manually using self-locking rotary dial in 1% increments (optionally with actuator or control drive)
  • With the right, constant conditions, correct installation and calibration, precision exceeds ±1 %, based on maximum stroke volume.
  • Wetted materials: PVDF, stainless steel 1.4571/1.4404, special materials on request
  • Patented multi-layer safety diaphragm with optical diaphragm rupture display (an option with diaphragm rupture warning system via a contact)
  • Integrated hydraulic relief and bleed valve
  • A wide range of power end versions is available: Three-phase standard AC motor, 1-phase AC motor, motors for use in areas at risk from explosion and different flange designs for use in customer-specific motors
  • For areas at risk from explosion II 2G Ex h IIC T3 Gb X or II 2G Ex h IIC T4 Gb X (optional)
  • IP 55 degree of protection
  • High-strength fibreglass-reinforced plastic housing with excellent chemical resistance
  • For reasons of safety, provide suitable overflow devices during installation for all mechanically deflected diaphragm metering pumps.

The following list of applications are general examples of generally suitable applications for this product. Please contact your local sales representative to talk about the applicable use of this product in your specific case / environment.

  • Volume-proportional addition of chemicals in water treatment, e.g. sodium-calcium hypochlorite for the disinfection of potable water
  • Addition of chemicals depending on the measured value, e.g. metering of acid and alkali for pH neutralisation in wastewater treatment
  • Time-controlled addition of chemicals in the cooling water circuit
  • Pulse-controlled metering in the bottling of different volumes e.g. glycerin filling of manometers