Mine Safety Appliances Co (MSA)

MSAModel HGM-SZ -Single-Zone Refrigerant Monitor

SHARE

Precision monitoring for low-level refrigerant leak detection for small to medium size facilities. The HGM-SZ Single Zone (tube) Refrigerant Gas Monitor is designed for continuous monitoring of CFC, HFC, and HCFC refrigerants and halogen gases with a 1/4 in. O.D. tube up to 50 ft (15m) distance from measuring point to monitor. Three adjustable alarm levels with relay output designate leak, spill, and evacuation concentrations. Gas alarms and system fault conditions are indicated by visual and audible alarms. The Model HGM-SZ provides a system fault relay output and a 4 to 20 mA output for integration with remote monitoring equipment or building management systems.The HGM-SZ Single Zone (tube) Refrigerant Gas Monitor is designed to be used as part of a control system that helps to prevent the formation of a hazardous environment when properly installed and maintained.

Most popular related searches
  • Proprietary infrared (NDIR) sensor accurately detects the presence of a target gas down to an industry-leading 1 ppm Minimum Detection Level (MDL)
  • Sensor is not prone to false alarms caused by cross-interference from other gases or sudden changes in temperature or humidity
  • Gas library contains 50+ refrigerants, with Halogen, CO2 and NH3 versions available
  • Backlit display shows real-time concentration readings and makes configuration and self-diagnostics intuitive
  • High performance sampling pump for fast response times, including extending sample lines
  • Proprietary infrared (NDIR) sensor accurately detects the presence of a target gas down to an industry-leading 1 ppm Minimum Detection Level (MDL)
  • Sensor is not prone to false alarms caused by cross-interference from other gases or sudden changes in temperature or humidity
  • Gas library contains 50+ refrigerants, with Halogen, CO2 and NH3 versions available
  • Backlit display shows real-time concentration readings and makes configuration and self-diagnostics intuitive
  • High performance sampling pump for fast response times, including extending sample lines
  • Accuracy: ±1 ppm ±10% from 0-1000 ppm (refrigerants); ±10 ppm ±10% from 0-10,000 ppm (Ammonia); ±5 PPM ±5% from 300-1000 ppm (CO2)
  • Alarm: Integrated Audible / Visual Alarm
  • Altitude: 0 to 6,560 ft (2,000 m)
  • Ambient Temperature: 32 to 122°F (0 to 50°C)
  • Analog Communication: 4 to 20 mA
  • Approvals / Standards: CE, UL, CSA, EN 61010-1, EN 14624
  • Buzzer Volume: 80 dB @ 10 cm
  • Enclosure Rating: General Purpose
  • Expected Sensor Service Life: 10 Years
  • Humidity: 5 to 90 %RH, non condensing
  • Measuring Range: Refrigerants: 0 to 10,000 ppm, Ammonia: 25 to 10,000 ppm, Carbon Dioxide: 300 to 8,000 ppm
  • Operating Voltage: 100 to 240 VAC, 50 / 60 Hz
  • Power: 100 to 240 VAC, 50/60 Hz, 15W
  • Product Dimensions (L×W×H): 13.7” × 7.7” × 3.6” (350 × 195 × 95 mm)
  • Product Weight: 7 lbs. (3.2 kg)
  • Relay Rating: 3 alarm relays, 1 fault relay, SPDT
  • Resolution: 1 ppm
  • Sample Points: 3
  • Sampling Distance: 0 to 500' (0 to 150 m)
  • Sensitivity/Minimum Detection Limit: Refrigerants: 1 ppm, Ammonia: 10 ppm, Carbon Dioxide: 10 ppm
  • Sensor Channels: 1
  • Sensor Type: NDIR
  • User Interface: Backlit, graphic LCD 160 x 128 pixel; three status LEDs
  • Warranty: 2 Years
  • Wiring: 3 A @ 250 VAC, resistive load

Gas Name

  • FC-3284
  • FC-72
  • H1211 (R-12B1)
  • H1301 (R-13B1)
  • H2402 (R-114B2)
  • HFP
  • Novec 1230
  • Novec 4710
  • Novec 5110
  • Novec 7100
  • Novec 7200
  • Novec 7300
  • Novec 7600
  • R-11
  • R-113
  • R-114
  • R-12
  • R-1224yd(Z)
  • R-123
  • R-1233zd(E)
  • R-1234yf
  • R-1234ze
  • R-124
  • R-125 (FE-25)
  • R-134a
  • R-1336mzz(E)
  • R-1336mzz(Z)
  • R-21
  • R-22
  • R-227ea (FM-200)
  • R-23
  • R-236fa
  • R-245fa
  • R-32
  • R-401A
  • R-402A
  • R-402B
  • R-404A
  • R-407A
  • R-407C
  • R-407F
  • R-407H
  • R-408A
  • R-409A
  • R-410A
  • R-422A
  • R-422D
  • R-424A
  • R-426A
  • R-427A
  • R-438A
  • R-448A
  • R-449A
  • R-452A
  • R-452B
  • R-454A
  • R-454B
  • R-454C
  • R-455A
  • R-463A
  • R-500
  • R-502
  • R-503
  • R-507A
  • R-508B
  • R-513A
  • R-514A
  • R-717 (Ammonia)
  • R-744 (CO2)
  • R-744A Nitrous oxide (N2O)
  • Sulfur Hexafluoride (SF6)
  • Carbon Monoxide (CO)
  • FA-188
  • Broadband