Nacah Tech provides the process design, mechanical design, BMS (control system) design, material procurement and fabrication, installation supervision and commissioning of Thermal Oxidizer Systems with many available accessories such as LEL analyzer, flow meters, controls, waste heat recovery, preheaters, flame arrestor, id fan, and stack. Each system thermally decomposes the VOC’s in waste gases from Production facility with its given emission sources in air/gas. The TO system is designed based on the information supplied under the specification. Design, manufacture, deliver & commission TO system for use at a wide variety of industrial, process or other plants.

Most popular related searches

Flow rate:
Minimum, Normal, Maximum (large enough for economy of scale for RTOs or carbon concentrators?)

VOCs or composition:
% of each VOC or combustible (high concentration produces plenty of heat so direct TO may be best.)

Oxygen concentration:
% O2 (impacts burner selection and operation.)

Inert concentration:
Inclusion of lots of H2O or CO2 impacts design and burner selection

Temperature:
Slightly over ambient temperature could mean carbon cannot adsorb while much higher temperatures mean less auxiliary fuel required and easier to destroy but accommodations needed for high gas temperature.

Particulate presence:
High Particulate must be dealt with by TO design or auxiliary equipment addition

Acid production/presence:
Acid presence impacts TO design and addition of auxiliary equipment

Auxiliary fuel available:
Type of fuel to be fired impacts burner and TO design

N compound presence:
Nitrogen compounds impact TO design because N compounds can produce high levels of NOx.