NEMo - Model ERP -Formaldehyde Measuring Device
Measurement solution for performing specific diagnostics in ERPs. Conform to the decree 2015-1000. Nemo ERP is the first to our camera formaldehyde measurement cell of the quality of indoor air quality (IAQ) continuously measuring the containment (CO2) and formaldehyde with the performance levels required by IAQ. Running on battery, having internal memory as well as compatibility with IoT networks, it is easy to install in any type of building. The NEMo analysis stations are the only ones to provide an automatic report with the actual exposure of the children.
Ethera has a wide range of measuring instruments for Air Quality. Our solution NEMo ERP is a formaldehyde measuring device, light VOCs, CO2, temperature and humidity that will allow all establishments receiving the public to perform a one-time diagnosis for durations of between one day and one week . Continuous NEMo analysis tracks concentrations during the week and tracks actual children`s exposureunlike COFRAC methods that continue to sample overnight. Thanks to the different configurations, our range of NEMo is adaptable to any establishment (schools, laboratory, industries, swimming pools ...). IAQ has become an important issue in ERPs, especially for schools and crèches. Find thedecrypted ERP decree on our ERP application page.
- Automatic report
- Recording
- Connected
- Calculation real exposure
- Multiparameter
- Monitoring of Indoor Air Quality in Publicly Established Establishments
- Diagnosis of work environments around production and in offices
- Inspection of new buildings at reception and operation
- Control of the efficiency of filtration systems
- Evaluation of ventilation systems
- Exclusive and patented Ethera technology for continuous and selective measurement of formaldehyde.
- Measure of actual exposure to pollutants and identification of pollution peaks.
- Modular and evolutive, possibility of adding additional sensors (PM2.5 / PM10, VOC, Radon ...).
- Connected device for real-time access to measurements (Sigfox, LoRa, Bluetooth, Wifi, RJ45, GSM).
- Simple and ergonomic data management software, cloud interface and mobile application.
- Complies with the requirements of Decree 2015-1000 on monitoring of IAQ in ERPs.
- Automated reports directly exploitable with comparison to the guide values
FORMALDEHYDE:
- Detection method: Optical reading with nanoporous material consumable (patented technology)
- Measurement range: IAQ: 0 - 200 ppb (0-246 μg / m3); H & S: 200 - 2800 ppb (246-3444 μg / m3)
- Sensitivity: Up to 1 ppb
- Sampling method: Passive diffusive
- Comparison with DNPH Reference Method: <13%
- Consumable conservation: Storage before use: 12 months from the date of manufacture. Store between 2 and 8 ° C
- interfering: No significant interference known
CO2 / CONFINEMENT:
- Detection method: Non-dispersive Infrared Absorption Spectrometry (NDIR)
- Measurement range: 0 to 5000 ppm
- Resolution: 1 ppm
- Uncertainty: +/- 50 ppm +/- 3% of read value
- 90% response time: <30 seconds
- COVL (light volatile organic compounds):
- Detection method: Electrochemistry
- Measurement range: 30 ppb at 5 ppm
- Resolution: 1 ppb
- Uncertainty: +/- 40 ppb
- 90% response time: <30 seconds
- VOC detected: gaseous compounds containing up to 4 carbon atoms (aldehydes, alcohols ...).
- TVOC (total volatile organic compounds):
- Detection method: MOS
- Measurement range: 0 ppm to 128 ppm
- Resolution: 0.125 ppm
- Uncertainty: +/- 30%
- Response time: 90% <30 seconds
TEMPERATURE:
- Sensor type: CMOS
- Measurement range: -55 ° C to + 125 ° C
- Resolution: .08 ° C
- Precision: +/- 2 ° C from -25 ° C to 100 ° C (+/- 0.5 ° C after offset calibration)
HUMIDITY:
- Sensor type: capacitive
- Measurement range: 0 to 95%
- Resolution: 0.08%
- Precision: +/- 3% from 11 ° C to 89 ° C (+/- 7% on the rest of the range)
PRESSURE:
- Sensor type: CMOS
- Measurement range: 260 to 1260 hPa
- Resolution: +/- 0.02 hPa
- Precision: +/- 2 hPa
MAIN FEATURES:
- Sampling frequency: 10 minutes configurable (Formaldehyde calculated, CO2, T, P, HR, COVL, TVOC) 2 hours (formaldehyde)
- Terms of use: Temperature between 0 ° C and + 30 ° C. Humidity level between 30 and 70% (RH)
- Dimensions (L x W x H) approx. / Weight: 175 x 95 x 75 mm / 450 grams
- Power / Battery: Battery 5000 mA (autonomy up to 15 days, with a measurement every 10 minutes)
- Mains connection and charging by microUSB port Magnetic On / Off
- Viewing: Flashing LEDs, 3 colors configurable according to the mode of use
- Interface / Communication:
- MicroUSB
- Sigfox, LoRa or Radio Frequency with connection of several recorders via hub, NEMo connect
- Required configuration: Operating system: Windows 7 or later, Mac OS 10.9 or higher
- Guarantee
- Conformity
- 2 years parts and labor, excluding consumables
- Decree 2015-1000 for containment (CO2) and formaldehyde
- Decree 2012-14 for containment (CO2)
- contains:
- 1 recorder
- 1 USB power adapter
- 1 USB-MicroUSB cable
- 1 cap and 1 membrane for formaldehyde diffuser (to be changed every 6 months)
- 1 standard sensor Ref. 094 for NEMo optical reader NEMo notice
- USB key containing Profil`air Manager 2 software and operating instructions