Colorimetric system for monitoring of drinking water, mineral water or raw water for food production. Liquiline System CA80NO offers precise, regulation-compliant online measurement of nitrite. It supports you in meeting the specified limits in drinking water, mineral water or food production. Like all Liquiline System analyzers, it enables plug & play of up to four Memosens sensors – minimizing the installation effort. Automatic calibration and cleaning and the low reagent consumption reduce operating and maintenance costs. Advanced diagnostics with remote access ensure process safety.

Most popular related searches
  • Compliance with standard colorimetric measuring principle - naphthylamine method - following ISO 6777 and DIN EN 26777 ensures comparability to lab measurements.

  • Reduced operating costs through automatic calibration and cleaning.

  • Simple maintenance: no tools required.

  • Advanced diagnostics with remote access for increased process safety.

  • Fast commissioning and plug & play thanks to Memosens technology and user-friendly operation.

  • Easy upgrade of functionality - even to a complete measuring station - simply by adding modules and connecting Memosens sensors. Reduces installation effort.

Liquiline System CA80NO supports you in keeping the strict nitrite limits for:

  • Drinking water

  • Mineral water

  • Raw water for food production

  • Measuring principle

    Colorimetric

  • Characteristic

    Process analyzer for Nitrite in potable water

  • Size

    Cabinet

    793 x 530 x 417 mm

    31.22 x 20.87 x 16.42 in

    Stand housing

    1693 x 530 x 417 mm

    66.65 x 20.87 x 16.42 in

  • Design

    Open design, cabinet and stand housing

    High-Performance plastic ASA-PC, additional stand coated steel

  • Process temperature

    4 ... 40 °C (41 ... 104 °F)

  • Ambient temperature

    5 ... 40 °C (41 ... 104 °F)

  • Process pressure

    at atmospheric pressure, < 0.2 bar absolute

  • Sample flow rate

    min. 5ml/min (0,17 fl.oz/min)

  • Consistency of the sample

    Suspended solids content

    Turbitity < 50 NTU, aqueous, homogenized

  • Specials

    Easy upgrade to measuring station with up to four digital Memosens sensors

    Automatic calibration and cleaning

    User-configurable measuring, cleaning and calibration intervals

    Optional cooling module for standard solution

    2 channel version optional

    User-definable measuring ranges

    Modular design for easily extensible functionality

  • Application

    Limit value monitoring of nitrite for potable water and mineral water applications

  • Power supply

    100 ... 120 VAC / 200 ... 240 VAC ± 10%

    24 VDC ± 10%

    50 ± 1 or 60 ± 1,2 Hz

  • Output

    2x 0/4 ... 20 mA

    Modbus RS485/TCP (optional)

    Ethernet (optional)

    Alarmrelay

  • Input

    1 or 2 measuring channel

    1 ... 4 digital sensor inputs for sensors with Memosens protocol (optional)

  • Measurement range

    10 ... 500 µg/l NO2-N
    0,1 ... 1,0 mg/l NO2-N
    0,2 ... 3,0 mg/l NO2-N

  • Consumables

    Reagents and standard solutions CY80NO as well as cleaner CY800 are necessary for the operation. Regular maintenance is done with the parts of the maintenance kit CAV800.