Pulsar - Model NoiseBadge -Noise Dosimeter
The Pulsar NoiseBadge Personal Noise Dosemeter System allows you to assess and capture noise dose and true worker noise exposure. Buy on its own or as part of a complete noise measurement kit, containing a reader unit and charger.
Simply and accurately assess and capture noise dose and the true noise exposure of workers using the Pulsar NoiseBadge Personal Noise Dosemeter System. The UK Health and Safety Executive (HSE) recommends that employers should obtain a reliable estimate of employees’ exposures, and compare the exposure with the exposure action values and limit values. This dosimeter badge system is just the device to do this.
- The revolutionary dosimeter badge is a self-contained noise measurement device, also known as Personal Sound Exposure Meter (PSEM), that has no cables, displays or controls, making it the perfect solution for noise dosimetry, because units cannot be tampered with easily or damaged during measurements.
- A separate Decibel Reader unit communicates with the dosemeters and controls the programming, calibration, start-stopping, data logging, downloading and storing of measurements. All key measurement parameters can be viewed on its large clear backlit LCD display screen, which also displays a time history graph of worker’s daily noise exposure over an entire working day.
- The Reader contains an integral acoustic calibrator allowing the dosemeter to be calibrated prior to and following each noise measurement in accordance with international regulations; the dosemeter automatically achieves this by computing the Daily Exposure for European legislation or the Time Weighted Average for US-based legislation.
- Full ‘Time History’ information allows you to determine when key noise problems occur during a worker’s day.
- Collect all the data essential to meet compliance with occupational noise regulations at the touch of a button including LAeq, LEP,d, % Dose and TWA.
- Frequency weightings include ‘A’ weighted (range 70dB(A) to 130dB(A)). The additional ‘C’ frequency weighted peak Time History allows you to fully assess risks from impulsive noise in the workplace.
- Our effective, user-friendly software package, AnalyzerPlus, allows users to quickly analyse and transform the raw data into informative report formats, simplifying a potentially complex and time-consuming process.
Everything you need for compliance with occupational noise regulations supplied in one user-friendly package:
- Compact, extremely robust and lightweight
- Portable, accurate and easy to use
- No cables or controls, reducing the risk of damage, misuse or tampering.
- Meets International Standard IEC 61252:1997 for Personal Sound Exposure Meters & ANSI S1.25:1991 Personal Noise Dosimeters
- Meets EN 61000-6-3 (2007), EN61000-6-1 (2007) EMC generic emission and immunity standards for residential, commercial and light industrial environments
- The ideal system for compliant assessment of workers’ industrial noise exposures
- Unique size and shape, innovative functional design
- Programmable for compliance with most worldwide regulations
- ‘Shake-to-wake’ function of dosemeters to extend battery life and operating time.
- Ergonomic Decibel Reader Unit with Integral Acoustic Calibrator
- Infra-red communication between Reader Unit and dosemeters
- Rechargeable Nickel Metal Hydride (NiMH) battery
- Outstanding Analysis & Reporting software supplied as standard (licence-free)
- 7-year warranty*
- Intrinsically safe dosemeter available on special request.
- Ideal for lone workers, shift workers or those operating in several locations
- Suitable where people are working with moving machinery, or in difficult to reach areas
Typical industries where the Model 22 Pulsar NoiseBadge is used include:
Manufacturing, Construction, Utilities (Gas, Water & Electricity), Local Authority & Government, Shipping, Entertainment & Leisure, Education & Higher Learning, Highway Maintenance, Haulage & Transport, Rail, Agriculture, Aviation, Public Transport, Emergency Services (Hospitals, Fire, Police), Chemical, Open Cast Mining, Printing and Catering.
*1-year warranty extendable to 7 years with annual recalibration and service.
Pulsar Software
The Model 22 NoiseBadge system is supplied as standard with our easy to use AnalyzerPlus program. To assist new users, a step by step wizard reassuringly guides you throughout the set-up and download procedures and allows measurement data to be viewed, analysed and printed.
Pre-formatted report templates are provided to present your measurement data. These reports can be printed or exported into a number of formats including Word, Excel and PDF.
The fact that AnalyzerPlus have no licensing restrictions means the user is able to install the software onto multiple computers and laptops eliminating hidden costs and optimising user flexibility.
Accessories
Each noise dosemeter system is supplied with everything required to conduct a fully compliant noise survey.
Contained in each system is the:
- Model 22 NoiseBadge noise dosimeter(s) & leather mounting kit(s)
- Model 22-R Reader unit with integral acoustic calibrator
- Charger unit for 2, 5 or 10 dosebadges
- Hard attaché Case
- Power supply
- AnalyzerPlus Licence-free analysis and reporting software
- Batteries
- USB download cable
- Calibration certificates
- User manual
- 7-year warranty
Optional Accessories:
- WS22 protective windshields to protect against dust, moisture and noise generated by ‘spurious’ events
- RK1 Key-fob remote control
- Helmet mounts
Weight:
- Model 22 noise dosemeter: 45gms (1.6oz)
- Model 22-R Reader: 400gms (14oz)
Why not combine the Pulsar Model 22 NoiseBadge System with a Sound Level Meter and Acoustic Calibrator?
The hard kit case supplied for your dosemeter system has space for 5 individual dosemeters along with all of the standard accessories.
The dosemeter system kit case allows enough space for any combination of our Sound Level Meters such as the Pulsar Nova Model 44 Noise at Work Meter, an Acoustic Calibrator and a windshield. This allows the dosemeter kit to be transformed and adapted into a Safety Professional kit to provide you with a complete noise monitoring solution.