NTi Audio AG
  1. Companies
  2. NTi Audio AG
  3. Products
  4. NTi Audio - Model XL2 - Handheld ...

NTi AudioModel XL2 -Handheld Acoustic and Audio Analyzer

SHARE

The XL2 Audio & Acoustic Analyzer is an advanced, multifunctional instrument designed to cater to a wide range of audio and acoustic measurement applications. Combining the features of a professional sound level meter, acoustic analyzer, and vibration meter, the handheld device offers efficient and precise measurements. Its capabilities include real-time analysis, with options for live level assessments such as Lmin, Lmax, Leq, and Lpeak alongside frequency weighting and various time weightings. Results can be stored for documentation, with additional features like wav-file recording and voice notes. The XL2 supports real-time spectrum analysis with 1/1 or 1/3 octave-band resolution crucial for optimizing sound systems and acoustics, adhering to IEC 61260 class 0 standards. Data is easily transferable to a computer for analysis, with support for text and audio formats, enhancing its utility across fields such as architectural acoustics, noise control, and occupational health.

Most popular related searches

Numerous measurement variations are simultaneously available. Actual level (live), Lmin, Lmax, Leq and Lpeak may be measured in combination with frequency weighting A, C or Z and time weightings fast, slow and impulse. All results are simultaneously available and may be stored automatically for later documentation.

Customers may log all acquired level information onto a removable SD card. Additionally the XL2 offers wav-file recording for a complete documentation of the measured sound pressure levels. Voice notes may also be added to each measurement.

The hand-held XL2 Analyzer is a powerful Sound Level Meter, a professional Acoustic Analyzer, a precision Audio Analyzer and a comprehensive Vibration Meter in one instrument. Easy operation and countless applications distinguish this quality Swiss product.

The XL2 Sound Level Meter is available in stock, allowing for expedited delivery.

At a glance

  • Reliable measurement solution
  • Flexible user interface
  • Extensive range of measurement functions

Standards

  • IEC 61672, IEC 60651, IEC 60804, IEC 61260
  • China: GB/T 3785:2010, GB/T 3241, GB 3096-2008, GB 50526, GB-T_4959-1995
  • Germany: DIN 15905-5, DIN 45645-2, optional: DIN 45645-1
  • Japan: JIS C1509-1:2005, JIS C 1513 class 1, JIS C 1514 class 0
  • Switzerland: SLV
  • UK: BS6698, BS5969
  • US: ANSI S1.4:2014, ANSI S1.43, ANSI S1.11:2014
  • SMPTE ST 202:2010, ISO 2969:2015

Sound levels

  • SPL actual, Lmin, Lmax, Lpeak, Leq, gliding Leq
  • Frequency weighting: A, C, Z (=flat) simultaneously
  • Time weighting: Fast, slow and optional impulse simultaneously
  • Correction values k1, k2
  • Indicators show when sound level limits are exceeded
  • Digital I/O interface for the control of external peripherals
  • Sound Exposure Level LAE (optional)
  • Percentile statistics for Lxy (x= A, C or Z, y= F, S or EQ1"): 1 - 99% (optional)
  • Calculated levels: LCeq - LAeq, LAIeq - LAeq, LAFT5eq -LAeq (optional)
  • Clock-impulse maximum level "TaktMax" in accordance with DIN 45645-1 (optional)

Logging and Reporting

  • All levels simultaneously
  • Short-time levels including spectrum for 1 second or longer
  • Wav-file for listening (compressed)
  • Data logging in 100 ms intervals (optional)
  • Linear wav-files with 24 bit, 48 kHz resolution (optional)

Remote measurement

  • Remote measurement acquisition (optional)

The RTA perfectly suits tasks such as optimization of sound systems and rooms. The XL2 measures and logs wideband values and the real time spectrum in 1/1 or 1/3 octave-band resolution according to IEC 61260 class 0. The sound level meter results of the wideband and RTA spectrum are simultaneously available.

Real Time Analyzer Features

  • 1/3 octave, 1/1 octave
  • Frequency weighting: A, C, Z (=flat)
  • Time weighting: Fast, slow and optional impulse
  • Percentile statistics for Lxy (x= A, C or Z, y= F or S ): 1 - 99% (optional)

Sound Level Meter - The Flexible Solution

The XL2 is a powerful sound level meter for events and environmental noise monitoring. Numerous measurement variations are available. Actual level, Lmin, Lmax and Leq may be measured in combination with frequency weighting A, C or Z and time weightings fast, slow and optional impulse. All results are simultaneously available.

All acquired level information can be automatically written to the removable SD card. The XL2 also offers wav-file recording for a complete documentation of the measured sound pressure levels. Additionally you may add a voice note to each measurement saved.

Sound Level Meter

  • Standards IEC 61672, IEC 60651, IEC 60804, ANSI S1.4, ANSI S1.43
  • Sound levels
    • SPL actual, Lmin, Lmax, Lpeak, Leq, gliding Leq
    • Spectrum 1/3 octave, 1/1 octave
    • Sound Exposure Level LAE (optional)
    • Percentile statistics for wide band, 1/1 and 1/3 octave spectrum:
    • 1%, 5%, 10%, 50%, 90%, 95%, 99% (optional)
    • Calculated levels (optional): LCeq - LAeq, LAIeq - LAeq, LAFT5eq -LAeq
    • Clock-impulse maximum level "TaktMax" according DIN 45645-1 (optional)
  • Logging to SD Card
    • All levels
    • Short-time levels including spectrum for 1 second or longer
    • 100 ms intervals optional
    • Wav-file (linear wav-files with 24 bit, 48 kHz optional)
  • Frequency weighting: A, C, Z (=flat)
  • Time weighting: Fast, slow and optional impulse
  • Correction values k1, k2
  • Limit monitoring showing exceeding sound levels
  • Digital I/O interface for the control of external peripherals
  • Remote measurement acquisition (optional)

Acoustic Analyzer

  • FFT Analysis
  • RT60 Reverberation Time
  • Polarity
  • Delay
  • Pass/Fail Measurements (optional)

STIPA Analyzer (optional)

  • Speech Intelligibility Measurement
  • IEC60268-16 (edition 4.0, 3.0 and 2.0), ISO 7240-16, ISO 7240-19, DIN VDE 0828-1, DIN VDE 0833-4
  • Ambient Noise Correction
  • Automated Averaging
  • Modulation Indices

Audio Analyzer

  • Level RMS
  • THD+N
  • Frequency
  • Scope

Real Time Analyzer RTA

The RTA perfectly suits tasks such as optimization of sound systems and rooms. The XL2 measures and logs wideband values and the real time spectrum in 1/1 or 1/3 octave band resolution in accordance with IEC 61260 class 0. The sound level meter results of the wide band and RTA spectrum are simultaneously available.

Acoustic Analyzer

FFT Analysis

The real-time FFT is the ideal tool for visualization of comb filters and narrow band effects. It measures the actual level and the averaged level Leq in three ranges over the entire audio band. The optional Extended Acoustic Pack offers an additional high-resolution Zoom-FFT up to 0.4 Hz steps in the frequency range 5 Hz - 20 kHz. The Spectral Limits Option extends the FFT Analysis with trace capturing, relative curve display and comprehensive tolerance handling.

RT60 Reverberation Time

The XL2 measures the energy decay in the range from 63 Hz to 8 kHz by the Schroeder method in 1/1 octave bands. Automatic triggering and averaging of multiple measurements simplifies the operation and minimizes the measurement time. Use either an impulse source or an interrupted pink noise as the test signal. The optional Extended Acoustic Pack extends the RT60 measurement to a 1/3 octave resolution.

Polarity

For a stereo sound image, it is important to match the polarities of the left and right speakers. The XL2 measures the polarity of cables, single speakers and speaker cabinets. The detailed result page displays the measured polarity as octave bands from 125 Hz to 8 kHz. This allows in-depth verification of the polarity - frequency relation. The polarity test signal is provided by the NTi Audio Test CD or the Minirator test signal generator.

Delay Time

The delay function supports the accurate setup of delay lines and thus the optimization of the directionality of the signal source. The XL2 measures the delay time between the electrical reference signal and the acoustic signal from the speaker. The required delay settings are displayed automatically, allowing the audio engineer to set the measured delay time directly into the delay device in the rack.

Speech Intelligibility STIPA (optional)

The XL2 Analyzer measures speech intelligibility according to the latest revision of standard IEC 60268-16:2011 (edition 4) as well as older revisions. It offers ambient noise correction and automated averaging for consecutive measurements. The XL2 displays the measurement results as STI or CIS, accompanied by the individual levels and modulation indices of the seven octave bands.

The measurement results are acquired from the dedicated STIPA test signal source:

  • NTi Audio TalkBox
    Acoustic signal generator, required for audio systems that include voice microphones, allows the entire signal chain to be measured.
  • Minirator MR-PRO
    Test signal generator, required for audio systems with line inputs
  • STIPA Test CD
    (included)

1/12 Octave Band Analysis (optional)

The Spectral Limits Option extends the function range of the XL2 with a 1/6th and 1/12th octave RTA analyzer. The XL2 Analyzer compares spectral measurements against a tolerance band and shows exceptions in every frequency band. This passed/failed condition is further visualized by the limit button and forwarded to the I/O interface of the instrument in order to drive an external alarm device such the accessory Stack Light.

Noise Curves (optional)

The noise curve measurement provides an objective rating of the background noise level in a room or environment. The noise curve rating of a spectrum is designated as the value of the highest noise curve “touched” by the measured octave-band spectrum. The speech interference level (SIL) and the noise curve rating are calculated in parallel. The Noise Curve function is offered with the Spectral Limits Option.

Supported noise curve measurements and standards:

  • Noise Rating (NR)
    in accordance with ISO 1996
  • Noise Criteria (NC)
    in accordance with ANSI 12.2-2008 and -1995
  • Room Noise Criteria (RNC)
    in accordance with ANSI 12.2-2008
  • Room Criteria (RC)
    in accordance with ANSI 12.2-1995
  • Preferred Noise Criteria (PNC)
    in accordance with ASA 1971

Analog Audio Analyzer

Level RMS / THD+N

The XL2 with balanced XLR and unbalanced RCA inputs offers a comprehensive, high performance audio analyzer. It simultaneously measures balance, level, distortion (THD+N) and frequency. The internal loudspeaker or headphone output offers audible monitoring of either the input signal or just the residual distortion. The optimized low distortion and low noise design enable level measurements down to -112 dBu and residual distortions typically lower than -100 dB, which is unmatched in handheld instruments.

Audio Spectrum

Spectral audio measurements are offered in the units Volt, dBu and dBV within the following measurement functions:

  • Sound Level Meter
  • FFT
  • 1/12 Octave (optional)

Scope

The scope function visualizes the waveform of the electrical input signal. It triggers to the fundamental frequency and selects the scaling of the X-axis (time) and Y-axis (level) automatically. The fundamental or most dominant frequency is displayed above the scope screen.