The TC-08 thermocouple data acquisition module is designed to measure a wide range of temperatures using any thermocouple that terminates in a miniature size thermocouple connector. Additionally the TC-08 can also measure other sensors using a ±70 mV range. Featuring built-in cold junction compensation (CJC), the TC-08 has an effective measuring range of -270 to 1820°C (the actual temperature range depends on the thermocouple type being used).

Most popular related searches
  • Measures from -270 to 1820°C (-454 to 3308°F)
  • Accepts Thermocouple Types J, K, T, E, R, S, B and N
  • Automatic Cold Junction Compensation
  • High Accuracy and Resolution
  • Multiple Units Can Be Run On a Single PC
  • 10 Readings Per Second
  • Windows Software Included: TC-08 Recorder and TC-08 Player
  • USB Interface

The TC-08 can be used with thermocouple types J, K, T, E, R, S, B and N and outputs can be viewed in degrees F, C or mV. The unit is accurate to 0.2 percent ± 0.5 degrees C and has a resolution of better than 0.1 degrees C for most thermocouple types.

The TC-08 connects to the USB port of a Windows based PC and enables the host PC to automatically detect the TC-08 avoiding the need for any complex setup procedures. The USB connection also allows the TC-08 to be powered directly by the USB bus eliminating the need for an external power supply and making the TC-08 ideal for measuring temperatures both in the lab and in the field.

The TC-08’s USB connectivity allows up to 20 TC-08 USB data acquisition modules to be used simultaneously on one PC making the TC-08 ideal for use as a large multi-channel temperature acquisition system with a cost per channel significantly lower than other systems of this size. The low conversion time of the TC-08 means up to 10 temperature measurements can be taken every second, while the high (20 bit) resolution ensures that the TC-08 can detect minute changes in temperature. With the TC-08 thermocouple data acquisition module your measurements can be made both fast and accurately. Simply plug the TC-08 into a USB port on your computer, connect your thermocouples, and you are ready to measure temperatures.

With the included TC-08 Recorder software, you can configure multiple (USB) TC-08s, set the sampling interval from 0.1 seconds to several hours and set the maximum number of readings. You can also tell TC-08 Recorder what to do once the thermocouple readings have been taken - either: Stop; Repeat Immediately (start again); Scroll (oldest recordings disappear); or Repeat After Delay (where the delay is set by the user). Mathematical operations can also be performed on the thermocouple outputs: for example to output one temperature relative to another.

  • Number of Channels:8
  • Conversion Time:100 ms (thermocouple and cold junction compensation)
  • Temperature Accuracy:Sum of  ±0.2% of reading and ±0.5°C
  • Voltage Accuracy:Sum of ±0.2%  of reading and ±10 µV
  • Overload Protection:±30 V
  • Maximum Common Mode Voltage:±7.5 V
  • Input Impedance:2 M.
  • Input Range (Voltage):±70 mV
  • Resolution:20-bits
  • Noise Free Resolution:16.25-bits
  • Thermocouple Types:B, E, J, K, N, R, S, T
  • Input Connectors:Miniature thermocouple
  • Output Connector:USB cable supplied 1.8 m (6`)
  • PC Connection:USB 1.1
  • Power Supply:From USB port
  • Dimensions:
    • 201 x 104 x 34 mm
    • (7.91 x 4.09 x 1.34 in)
  • Included Software:TC-08 Recorder and Player
  • PC REQUIREMENTS
  • Processor:Pentium class processor or equivalent
  • Memory:32 MB minimum
  • Disk space:10 MB minimum
  • Operating System:32-bit or 64-bit versions of WIN XP (SP2 or above)/VISTA/WIN 7
  • Ports:USB 1.1 or USB 2.0 compliant port.  Must be connected direct to the port or a powered USB hub