Onset HOBOModel U12-012 -Temperature/Relative Humidity/Light/External Data Logger

SHARE

Measure temperature, relative humidity, light intensity, and more with the HOBO U12-012. With 12-bit resolution measurements, this data logger gathers a range of recorded data and stores 43,000 measurements.

Most popular related searches
  • 12-bit resolution provides high accuracy
  • Large memory for long-term deployments or fast sampling
  • Programmable and push button start
  • Direct USB interface for fast data offload
  • Compatible with Onset’s HOBO U-Shuttle for convenient data transport
  • Compatible with HOBOware and HOBOware Pro for logger setup, graphing and analysis

Environment:
The U12-012 Data Logger is for use inIndoor environments

Measurements:
The U12-012 Data Logger supports the following measurements (some sensors sold separately):

Temperature, Relative Humidity, 4-20mA, AC Current, AC Voltage, Air Velocity , Carbon Dioxide, Compressed Air Flow, DC Current, DC Voltage, Gauge Pressure, Kilowatts (kW), Light Intensity, Volatile Organic Compound

Measurement range:

  • Temperature: -20° to 70°C (-4° to 158°F)
  • RH: 5% to 95% RH
  • Light intensity: 1 to 3000 footcandles (lumens/ft2) typical; maximum value varies from 1500 to 4500 footcandles (lumens/ft2)
  • Analog channels: 0 to 2.5 Vdc (w/CABLE-2.5-STEREO); 0 to 5 Vdc (w/CABLE-ADAP5); 0 to 10 Vdc (w/ CABLE-ADAP10); 4-20 mA (w/CABLE-4-20MA)

Accuracy:

  • Temperature: ± 0.35°C from 0° to 50°C (± 0.63°F from 32° to 122°F)
  • RH: ±2.5% from 10% to 90% RH (typical), to a maximum of ±3.5%
  • Light intensity: Designed for indoor measurement of relative light levels
  • External input channel (see sensor manual): ± 2 mV ± 2.5% of absolute reading

Resolution:

  • Temperature: 0.03°C at 25°C (0.05°F at 77°F)
  • RH: 0.03% RH

Sample Rate:
1 second to 18 hours, user selectable

Drift:
  Temperature: 0.1°C/year (0.2°F/year)
RH:

Response time in airflow of 1 m/s (2.2 mph):

  • Temperature: 6 minutes, typical to 90%
  • RH: 1 minute, typical to 90%
  • Time accuracy: ± 1 minute per month at 25°C (77°F)

Operating temperature:

  • Logging: -20° to 70°C (-4° to 158°F); 0 to 95% RH (non-condensing)
  • Launch/readout: 0° to 50°C (32° to 122°F), per USB specification
  • Battery life: 1 year typical use
  • Memory: 64K bytes (43,000 12-bit measurements)
  • Weight: 46 g (1.6 oz)
  • Dimensions: 58 x 74 x 22 mm (2.3 x 2.9 x 0.9 inches)

The CE Marking identifies this product as complying with all relevant directives in the European Union (EU).