OTT HydroMet - Veralto
  1. Companies
  2. OTT HydroMet - Veralto
  3. Products
  4. OTT - Model RLS 500 - Smart Radar Level ...

OTTModel RLS 500 -Smart Radar Level Sensor, SDI-12, Imperial

SHARE

The OTT RLS 500 is a next generation radar level sensor designed for reliable water level measurement. With advanced 80 GHz technology, robust IP67 housing, and seamless integration capabilities, the OTT RLS 500 ensures accurate data collection with minimal maintenance and low total cost of ownership.



Most popular related searches
Reliable and Robust Design for Peace of Mind

Ensure extended sensor lifetime with IP67 housing and a low power, maintenance-free design so you can focus on managing projects without worrying about equipment failure.

Trust in Your Data for Confident Decision-Making

Achieve unmatched accuracy and long-term stability by reducing the need for verification measurements, resulting in high-quality data for stakeholders that meet standards.

Operational Efficiency to Optimize Resources

Remotely determine device health with smart sensors and metadata, improving maintenance schedules and minimizing unplanned field visits, thus reducing time in the field.

Hydrology-Tailored Design for Seamless Integration

Designed by hydrologists for hydrologists, discretely deploy the compact sensor and integrate effortlessly into existing networks, ensuring your historical data record is preserved.

*Value Processing:

  • Mean value over a time period
  • Minimum value within a time interval
  • Maximum value within a time interval
  • Median over a time period
  • Standard deviation over a time period
  • Hydrological discharge (Q)
  • Interface: SDI-12 and RS-485 (SDI-12 V1.4 and Modbus RTU)
  • Level Accuracy: ±2 mm
  • Material:
    • Housing: AlMgSi1, ASA (UV-stabilised ABS)
    • Radom (front plate): TFM PTFE
    • Mounting: 1.4301 (V2A)
    • Cable: PUR
    • Cable connector: M9
  • Parameters Measured:
    • Water level / depth to water
    • Internal relative humidity
    • Sensor orientation
  • Power Consumption
    • Active: < 4 mA
    • Idle: < 250 µA
  • Power Supply: 5.5 … 28.8 V DC, typ. 12/24 V DC
  • Protection Class: IP 67 flooding without damage for 1 week / 1 m water column (bottom housing)
  • Protocol over RS485: SDI-12
  • Range: 0 … 30 m (98 ft); distance to water
  • Resolution: 0.001 m · 0.1 cm · 1 mm (0.01 ft · 0.1 inch)
  • Sampling Option: 2 Hz Standard
  • Unit System: Imperial