PermAlert, a division of Perma-Pipe, Inc.

PermAlertModel AGT-Gold -Wicking Sensing Cable for Chemical Detection

SHARE

The AGT-Gold is a wicking sensing cable designed for fast reaction time when come in contact with liquid. The AGT-Gold is capable of detecting water, and corrosive chemicals. Wicking cable with fast reaction time designed for high sensitivity used. Cable works with water and chemicals.

Most popular related searches
  • Durable Design
  • Chemical and Corrosion Resistant
  • Dust and Contaminant Resistant
  • Fast Respond Time

PermAlert is the leak detection and location systems technology specialist since 1988. We work with customers to address their most complex leak detection challenges and to deliver innovative business solutions that bring higher value to every facility.

PermAlert offers continuous monitoring, multi-level alerts, system logging, BMS integration, and cost savings to the data centers, oil & gas, commercial buildings, and healthcare industries.

No matter where the leak location is, we are confident that our stability as a company, team of technical expertise, and international network are at your disposal to help minimize leaks and to maximize asset protection.

Overview

The PAL-AT family of sensor cables are able to meet the specific requirements of a wide variety of applications and environments including subfloors, containment pipe systems, direct burial and foam insulated pipes. The sensor cables offer the leak detection designer flexibility and choice in selecting the proper cable for the desired system sensitivity.

All PAL-AT cables and connectors are easily spliced or repaired in the field to minimize downtime and repair cost.

PAL-AT AGW-Gold and AGT-Gold sensor cables have the ability to detect both water-based and hydrocarbon liquids.   This reduces the number of sensor cables required in many applications.

Each of these PAL-AT sensor cables can be dried and reused after a water-based or volatile hydrocarbon leak has been cleaned up. These cables have no exposed metal and are designed for corrosive chemical applications. Each individual strand of braid wire is coated with a high-temperature, corrosion-resistant polymer and the length of the cable is covered with a fluoropolymer overbraid. Because there is no exposed metal, the Gold cables eliminate the need for special isolation precautions in cathodic-protected pipe applications.

PAL-AT TFH-Gold hydrocarbon sensor cable uses a hydrocarbon permeable core to detect hydrocarbon liquids while ignoring water-based liquids. In most cases, the sensor cable must be replaced after exposure to hydrocarbons.

AGT-Gold is a wicking cable that is chemically resistant and designed to detect highly corrosive acid, base, and solvent leaks. Typical applications are clean rooms, subfloors, aboveground single-wall pipes (water-based liquids only) and equipment applications. AGT-Gold should be installed in temperature and humidity controlled environments. This cable requires more drying time than AGW-Gold. Must be replaced after exposure to hydrocarbons.

Sensitivity is the length of wet cable that is required to activate the PAL-AT under standard sensitivity settings. The length required for quick-drying AGW-Gold refers to the submerged length of the cable. Wicking cables AGT-Gold and TFH-Gold will quickly draw a liquid into the cable through capillary action when it is in contact with a 1/16" (2 mm) film of liquid. The length of wet cable required for wicking cables is the saturated length of cable. For example, if a few inches of AGT-Gold cable contact a film of water at 5,000 ft (1,500 m), in less than two minutes, the cable will be saturated sufficiently and the PAL-AT will go into alarm. The PAL-AT sensitivity can be adjusted.

Sensor cable shall be of fluoropolymer and polymer coated wire construction with no exposed metal parts. Sensor cable shall detect accumulations at a shallow depth of 1/16" (1.5 mm) and be resistant to most acids, bases and solvents and be capable of being flushed and dried in place (water-based liquids). The cable will not require replacement after a leak event of any compatible and/or volatile liquid. The cable shall have a breaking strength of at least 100 lb (45 kg) and shall be resistant to corrosion, abrasion and most chemicals tested in accordance with exposure procedures in ASTM D-543.

24X7 MONITORING
Continuous monitoring of critical infrastructure and equipment,

MULTI-LEVELALERTS
Capable of detecting multiple and growing leaks while maintain continuous operations.

SYSTEM LOGGING
Every leak detection event is recorded in system log to allow full audit trail and ease of troubleshoot,

BMS INTEGRATION
Support BMS integration via RS485, Modbus, BACnet and dry contacts,

COST SAVINGS
Minimize downtime and damages to critical infrastructures, And reduction of insurance premium.