Aquacell - Model P2-C00LB0X -Portable Wastewater Samplers
Incorporated within the P2-COOLBOX is a high performance passive Sample Temperature Control facility. This ensures that the collected samples are preserved at an optimal temperature (0°C to 5°C up to 5 days) whilst awaiting collection / inspection. This is particularly useful when sampling biologically active wastewater
The Aquacell P2-COOLBOX is designed typically to operate at sites where the sampling requirement is infrequent or there is simply no power available. This high performance Portable Sampler makes a very practical alternative to installing a Stationary Sampler with Sample Temperature Control and the associated costs
Thick wall insulation combined with sealed ‘no mess’ Cooling Elements provides for impressive sample temperature control performance. As the sample temperature control system is passive and therefore does not require any electrical power, the P2-COOLBOX’s power source (normally an Integral Battery) is required only to power the Sampling Module and therefore maximises the operating period
The P2-COOLBOX can be supplied with a Sample Temperature Monitoring Facility, with this option the minimum, maximum, average and present sample temperatures can by monitored on the Aquacell display. Additionally all the Aquacell Samplers can be fitted with a Data Connection facility. This enables the download of logged sample temperature data from the Sampler Module to a PC (or similar) via the USB connection
As with every Sampler in the Aquacell range the P2-COOLBOX incorporates the well proven and dependable Aquacell Module
- MCERTs compliant
- Incorporates 2 `no mess` Cooling Elements
- 5 litre HDPE Sample Container
- Upto 5 day cooling capability (dependant on environmental conditions)
- Suitable for indoor and outdoor use
- Supplied with easy clean 5 litre composite Sample Container with lid
- Mains and / or Battery powered
- Seperately lockable Sampler Cover and COOLBOX base
- 350+ samples achievable with a fully charged Aquamatic Battery
- Via the Ancillary Signal Connection all models can be connected to, and controlled by, external equipment such as Flow Meters, pH Meters, PLCs etc.
- Power Options
- 12VDC (Integral or External)
- 110 / 220 / 230VAC/50hz
- Sample Collection Vessel compatibility:
- Supplied with Single 5 litre Container with Screw Lid
- Dimension: 835x430x430mm(HxWxD)
- Weight: 17.3kg (including detachable COOLBOX Base)
- Intake Hose length: 2m (with optional 2m Intake Hose Extensions availabale)
- Supplied with 2 x Sealed `no mess` Cooling Elements
- Ambient working temperature range: -10°C to 50°C