AW-Lake - Model JV-TC -Positive Displacement Flow Meters
Measuring Accuracy: ±0.5% over full range with 30cP fluid, ±0.25% optional with select sensors
Six Flow Ranges: 0.001 - 20 gallons per minute | 1.4 -28,800 gallons per day (see specs below for ranges of each meter size)
Pressure Rating: Up to 6,000 psi
Calibration: 7-point logarithmic calibration
Output Options: Wide variety of options: see "Choose Your Sensor" tab below for details
-
The JV-TC positive displacement flow meters build upon the performance you expect from us and take ease of use and durability to the next level, offering greater efficiencies in operation with higher resolution, higher standard pressure rating (up to 6,000 psi), wider turndowns, and improved accuracy – even in changing viscosity conditions.
- Eliminate Waste – Maintain repeatable and accurate flow measurement, independent of changing fluid conditions. Track and report usage to quantify product/process quality, pump performance, or material levels.
- Reduce Costs – By using the correct amount of expensive/costly fluids in your process and not overdosing, you can reduce material costs. And with proper lubrication or chemical dosing you can reduce maintenance costs.
- Improve Product Quality – With flow meters that can ensure ±0.1% repeatability, you are able to maintain consistency in your processes by assuring each batch is the same. Despite long and continuous operation, these meters perform at the same level month after month… year after year.
- Operate with Ease – Paired with our smart EDGE family of flow sensors there is one easy to learn set-up procedure available via phone or PC app. Our friendly & knowledgeable staff of Application Engineers are here to help you select the right meter and get you up and running quickly.
- Enjoy Flexibility – The new meters were designed to seamlessly integrate with the EDGE sensors, which are available in panel mount, local mount, and battery, loop, or DC powered displays. Choose your output as well: Frequency or Analog (voltage or 4-20mA), or Modbus.
MEASURING ACCURACY:
± 0.5% over full range with 30cP fluid, ± 0.25% optional with select sensors
REPEATABILITY:
± 0.1%
FLOW MEASURING RANGES:
JVx-10TC: 0.001 to 0.5 gpm | 1.4 to 720 gpd | 0.004 to 1.9 lpm
JVx-12TC: 0.005 to 0.8 gpm | 7.2 to 1152 gpd | 0.02 to 3.0 lpm
JVx-20TC: 0.02 to 2.0 gpm | 28.8 to 2880 gpd | 0.08 to 7.6 lpm
JVx-30TC: 0.1 to 7.0 gpm | 144 to 10,080 gpd | 0.38 to 26.5 lpm
JVx-60TC: 0.1 to 20 gpm | 144 to 28,800 gpd | 0.38 to 75.7 lpm
MAXIMUM OPERATING PRESSURE
up to 6,000 psi
MAXIMUM FLUID TEMPERATURE
Depends on sensor used, refer to sensor page
PORTS:
NPT standard; BSPP and bottom manifold mount optional
MATERIALS OF CONSTRUCTION:
Body: JVM = 303 Stainless Steel, JVS – 316L Stainless Steel
Gears: Stainless Steel (DIN 1.4122)
O-Ring: FKM, FFKM, or PTFE
Bearings & Shafts: Tungsten Carbide
Bolts: Zinc Flake Coated Carbon Steel