Postnova - Model PN3211 -UV Detector
The PN3211 UV Detector provides an exceptional level of sensitivity and stability. As a high sensitive UV detector the PN3211 has a noise level of 0.5×10-5 AU max., making it one of the most sensitive UV detectors (ASTM Standards).
Most popular related searches
low pressure mercury lamp
flow cell
wavelength calibration
digital temperature controller
mercury lamp
noise control
ASTM standard
PFAS
flow control
mercury calibration
- Greater Baseline Stability
Supplied as standard, a temperature-controlled flow cell eliminates inconsistencies caused by changes in absorbance due to shifts in room temperature. This helps increase the baseline stability and the analysis reliability.
- Superior Linearity - 2.5AU
Using newly developed signal processing technology, the stray-light correction function has been enhanced, and the linearity has been improved. This expanded linearity combines with various noise-reduction technologies to provide users with a wide dynamic range and allow for the analysis of your target compound and minor impurities in a single run.
- Internal Validation Protocol
The incorporation of a low-pressure mercury lamp for wavelength calibration ensures simple calibration in the ultraviolet region.
- Dual-Wavelength Measurement
Monitor two components in the UV range simultaneously.
Flow Cells
- Z-DET-3211-001 Analytical, Peek
- Z-DET-3211-002 Analytical, Stainless Steel
- Z-DET-3211-003 Preparative, Stainless Steel
Detector Lamps
- Z-DL-PN3211 D2-Lamp, Pre-aligned, Longlife
- Light Source: Deuterium lamp
- Wavelength Range: 190 – 700 nm
- Wavelength Accuracy: ± 1 nm
- Noise Level: ± 0.25x10-5 AU max.
- Drift:
- 1x10-4 AU/h max. (250 nm, room temperature constant, air in cell)
- 3x10-4 AU/h max. (250 nm, room temperature fluctuation less than 2°C, air in cell)
- Operating Temperature: 4 - 35°C
- Cell Temperature Range: 5°C above room temperature to 50°C, at 1°C steps
- Response: 11 steps selectable (corresponding to time constant 0.02, 0.05, 0.1, 0.5, 1.0, 1.5, 2.0, 3.0, 6.0, 8.0, 10.0 sec)
- Range: 0.0001 – 2.56 AUFS (selectable in 0.0001 AUSF steps)
- Zero Adjustment: Auto zero function, baseline shift function
- Wavelength Steps:
- 1–5 nm, selectable in 5 steps
- 2–5 nm when W lamp is used
- Scanning Speed: 10 – 50 nm/sec, in 5 steps
- Spectrum Plot: output speed 1, 3, 10 nm/sec
- Optical Path Length: 10 mm
- Cell Volume: 12 μL
- Pressure Resistance: 12 MPa
- Wetted Surface Materials: SUS316L, quartz, PFA
- Dimensions (WxHxD)/Weight: 260 x 140 x 420 mm; 13 Kg
- Power Requirements: 100/120/220-240 V, 50/60Hz