Procast techModel ZA, ZE -Chemical Process Pump

SHARE

ZA, ZE Chemical Process Pump is designed in accordance with APl610 specification for single-stage, horizontal volute pump. Suitable for conveying clean or contain particles, low or high temperature, neutral or corrosive liquids. Mainly used in oil refineries, petrochemical industry, coal processing and cryogenic engineering, chemical industry, paper, pulp and paper industry, sugar industry and the general process industries, environmental engineering, shipbuilding and maritime industry, desalination plants and power plant.

Most popular related searches

Example: ZA(ZE)80-40-200A

  • ZA- Chemical process pump 
  • ZE- Chemical process pump
  • 80-diameter of pump suction(mm) 
  • 40-diameter of pump outlet(mm)
  • 200-nominal diameter of impeller(mm)
  • A- First time of cutting outer diameter of impeller
  • Capacity:3 -2600m³/h
  • Head:4 -250m
  • Speed:2950r/min,1475r/min

              ZA type pump:

  • Temp:-80℃~+175℃ Maximum operation pressure: 2.5MPa

              ZE type pump:

  • Temp:-80℃~+450℃ Maximum operation pressure: 5.0MPa
  • Single-stage, single-suction, axial suction, radial discharge, horizontal centrifugal pump;
  • The balance hole and the front and rear sealing rings balance the axial force; the pump body with a larger outlet diameter adopts a double volute structure to balance the radial force;
  • Pump support: ZA series pump is a foot support structure, and ZE series pump is a horizontal centerline support structure.
  • The shaft seal cavity and the pump cover are cast as a whole. It can be sealed with packing or mechanical seal. Mechanical seals are divided into single-end mechanical seal, double-end mechanical seal, bellows seal, tandem seal, etc.;
  • According to APl682 standard, equipped with mechanical seal cooling, flushing or sealing liquid auxiliary piping system;
  • When the temperature of the medium exceeds 105°C, water cooling and bearing water cooling jackets are needed outside the shaft seal cavity.
  • When transporting media that is easy to freeze or crystallize, heat preservation is required outside the shaft seal cavity.
  • The rotation of the pump: turn clockwise from the motor end;
  • The pump inlet and outlet flanges are equipped with butt-welded steel flanges, and the connection type with the inlet and outlet pipelines of the device has national standards (GB/T9115.1-), chemical Ministry of Industry standard HG20615- (American system) and HG20595- (European system), three types are selected by users.