IMP+ can be used wherever you need reliable non-contacting ultrasonic level measurement and Pulsar`s DATEM echo processing means IMP+ is perfect for solids or liquids and anywhere you need a display telling you the level, or an analogue output to interface with your site control system or drive a display. There is an IMP+ to suit your application, 3m, 6m and 10m range versions are available and each can be wired for 2-wire and 3-wire operation. IMP+ features a LCD display and digital temperature measurement and compensation. IMP+ also has 2 relay outputs as standard.

Most popular related searches

When used on battery power for intermittent (wake-up) applications, IMP`s high speed boot up of circa 3 seconds maximises battery life. For example, if an IMP+ were switched on every 15 minutes for a 3 second reading, average current is a mere 40µA.

Active and passive (sourcing and sinking) analogue outputs assist with system integration, especially when retro-fitting into older installations.

IMP PC is optional software that extends IMP`s capabilities, allowing you to:

  • Download, analyse and store echo profiles. A great way to see exactly what is happening in the application. Fine tuning for ultimate performance.
  • Set-up IMP. All programming parameters are instantly visible in the IMP PC programming screens. Program the IMP unit on a desktop before installation, or clone a number of IMPs to save valuable time.
  • Updates. Future-proof your IMP! Pulsar`s policy of continuous improvement means that we never stop developing our products. IMP PC allows new firmware to be installed into your IMP PC units without even removing them from the application.
  • Flow Measurement. A flow curve may be added within IMP PC to configure for level to flow linearisation.
  • Level measurement
  • High speed boot up requirements
  • Narrow beam angle
  • Combined transducer and controller

PHYSICAL:

  • Dimensions: 175mm (6.9in) overall height x 130mm (5.12in) diameter
  • Cable entry: 2 off 16mm (0.63in) cable glands 3.5-10mm (0.14-0.39in) cable dia
  • Mounting: 1.5” (3m/10ft) and 6m/20ft) range versions), 2” (10m/33ft version) universal thread - suits BSP and NPT, parallel and tapered
  • Weight: Approximately 1kg (2.2lbs)
  • CE Approval: See EC Declaration of Conformity

ENVIRONMENTAL:

  • Temp. range (process): -40ºC to +80ºC (-40ºF to +176ºF)
  • Temp. range (ambient): -20ºC to +65ºC (-4ºF to +149ºF)
  • IP Rating: IP67

VARIANTS:

  • IMP3:
    • Beam angle(-3dB half power): <10º inclusive
    • Operating frequency: 125kHz
    • Measurement range: 0.2m - 3m (0.66ft - 10ft)
  • IMP6:
    • Beam angle(-3dB half power): <10º inclusive
    • Operating frequency: 75kHz
    • Measurement range: 0.3m - 6m (0.98ft - 20ft)
  • IMP10:
    • Beam angle(-3dB half power): <10º inclusive
    • Operating frequency: 41kHz
    • Measurement range: 0.3m - 10m (0.98ft - 33ft)

PERFORMANCE:

  • Digital echo processing: DATEM (Digital Adaptive Tracking of Echo Movement)
  • Input voltage range: 11 - 30V, 3.5 - 22mA
  • Accuracy: ±0.25% or 6mm/0.24in (whichever is greater)
  • Resolution: ± 0.1% or 2mm/0.08in (whichever is greater)
  • 4-20mA outputs: Resolution 5µA (both active and passive outputs)
  • Temperature compensation: Via internal temperature sensor (±0.5ºC accuracy). Level and volume conversion are installed allowing linearisation for tank shapes
  • IMP may be wired as either 2-wire or 3-wire, giving the features below:
  • 2-wire configuration: RS232 (RJ11 port) connection for diagnostics and software updates
  • 4 digit LCD display
  • 4 button keypad for parameter entry
  • Power consumption: 3.5 - 22mA
  • Passive 4-20mA output
  • 3-wire configuration (additional to 2-wire): Backlit LCD display
  • 0-10V analogue output
  • 2 relays: single pole two way, 1A 30VDC/AC
  • Power consumption with relays energised <60mA (less 12mA/relay not energised)
  • Active and passive 4-20mA outputs
  • PC Interface - PC Suite: All parameters can be accessed and changed through PC Suite software. Echo traces may be viewed on screen.