identiFINDER - Model 2 -Radio-Isotope Identification Device
The identiFINDER 2 combines all of the same core signal processing electronics and performance capabilities as the original identiFINDER with several new features. The monochrome LCD display has been replaced with a TFT LCD, 64k colour, 320 x 240 pixel display that is readable in virtually any light conditions. The spectrum is continuously source peak or LED peak stabilised to handle a wide range of count rates and conditions. The advantage of the LED stabilisation technique is that there is no peak interference in the identification spectrum.
Wired communication uses a micro USB connector, USB 2.0, and wireless communication is via a Class 2.0 Bluetooth ® interface, with a 33ft (10m) range. Both communication methods support the reach-back capability provided with the identiFINDER 2. A web interface is provided via USB emulated TCPIP (LAN) for monitoring and configuring the unit. A 12 channel, SIRF III GPS is included for incident location. Data storage has been enlarged to 1GB to save more spectra and event information.
Features of the identiFINDER that remain unchanged:
- Size, shape and weight,
- Three button (fourth for power) operation
- Scintillation, Neutron and GM detector types, sizes and sentivities
- Screens and menu, when operated in the original identiFINDER mode
- Types of alarms
- Radionuclide identification accuracy
- TFT LCD 64k colour display
- LED stabilised
- 12 channel, SIRF III GPS
- Reachback via Bluetooth® connected to DUN capable cell phone
- ANSI N42.42 output format
- Web interface for monitoring and configuring instrument
- Original three button operation
- 1GB event data storage
- Visible, audible and tactile alarm annunciators
- Embedded windows CE operating system
- Meets ANSI N42.34 shock conditions
- Detector Types: Gamma: NaI, 1.4" x 2" / 35 x 51 mm
- High Dose Gamma: GM detector
- Neutron: Moderated He3 proportional detector, 0.6" x 2.1" / 15 x 54 mm @ 8 atm
- Gamma Energy Range: 20 keV to 3 MeV
- Dose Range: 0.01 µSv to 1 Sv / 1 µR to 100 R
- Neutron Sensitivity: 2.6 CPS/nv ± 20%
- Stabilisation: Cs137 source peak or LED peak
- ±1% for temperature change rate of <0.5°C/min
- Nuclide Identification: Per ANSI N42.34
- Memory: 1.8 GB
- Temperature: -4°F to +131°F / -20°C to +55°C
- Humidity: 10% to 80% non-condensing
- Dimensions: 9.75" x 3.67" x 2.95" / 248 x 93 x 75 mm
- Weight: 2.65 lbs / 1.2 kgs with neutron detector, 2.6 lbs / 1.18 kgs w/o neutron detector