HiMass CAST has been constructed for applications with specific requirements on higher total flow rate and total soot mass output. Followings are some examples of  the applications for HiMass CAST: Filter testing. Charging filter / loading DPF. Exhaust gas simulation. CVS calibration. Smoke simulation.

Most popular related searches
  • Real combustion soot particles
  • Diffusion flame
  • Fuel: propane, butane or liquid fuel (diesel, gasoline) with special burner on request
  • Rapid adjustable particle size in a range from 20 to 200 nm
  • Up to 10 g/h soot mass output or higher on request
  • Particle number concentration up to 108particle/cm3
  • Both unimodal and bimodal size distributions possible
  • 3 default operation points (particle size and mass concentration remain on request adjustable for user configuration)
  • High stability and repeatability in size and concentration
  • Reproducible physical and chemical characteristics
  • No condensation of water in the particle stream
  • No soot contamination within the main device
  • Operation pressure: free for open and sealed system, optional up to 500 mbar, or higher on request.
  • Sufficient exhaust amount, total flow rate of undiluted exhaust gas: 500 l/min, additional dilution possible on customer request
  • Internal ignition with flame safety device
  • Sight glas for flame inspection
  • Easy handling and portable
  • Smart design with 1.3 m and 0.3 m2 (H x S)
  • height of particle outlet: adjustable 40 – 120 cm
  • burner mobile on a separate plat form for remote operation
  • internal ignition and with flame failure device
  • sight control of the flame
  • red button for emergency stop of total system
  • Soot particle: similar morphology to diesel soot particle
  • Particle size range: 20-200 nm, >300 nm with suppl. Equipment (optional)
  • Particle size distribution: mono-modal
  • Concentration range: up to 108 particle/cm3
  • Undituted Smoke/Exhaust gas: 500 l/min (30 m3/h)
  • Flow rate of dilution: min. 1500 l/min (90 m3/h) recommended
  • Mass output: up to 10 g/hour or higher on request
  • Temperature of aerosol flow: 70-140 ºC
  • Mass determination / Calibration: gravimetric analysis of soot sample on filter
  • Repeatablility: <5%
  • Fuel requirement: Oil free, industry quality
  • Oxidation and dilution air: Ambient air
  • Quench gas: Ambient air
  • Power requirements: 115/220V
  • Device dimension (LWH): 130 cm x 65 cm x 55 cm