Rembe GmbH
  1. Companies
  2. Rembe GmbH
  3. Products
  4. REMBE - Model EGV - Explosion Venting ...

REMBEModel EGV -Explosion Venting System

SHARE

From spray dryers, elevators and chain conveyors to screens with light vibration, silos with mechanical filling and cyclones – the EGV is suitable for use in a wide range of applications in all sectors for both non-pressurised processes and processes with low vacuum or overpressure (up to 50 % of static burst pressure). The standard burst pressure is 0.1 bar at 22 °C (71.6 °F).

Most popular related searches

When pressure rises, the explosion vent opens at the defined breaking point and releases pressure out of the vessel into the surrounding area.

  • High venting capacity and full bore opening due to low  surface weight.
  • High stability and opening speed through integrated bionic structure.
  • Direct installation of the explosion vent even on round  vessels prevents accumulation of deposits and bacteria  formation. No complicated flange constructions required.
  • Adapts perfectly to your process due to the wide range  of EGV geometries available.
  • Quick and easy installation as EGV is torque independent.  No additional counter frame required.
  • Significant space savings due to the integrated gasket and frame in the explosion vent.
  • Guaranteed leaktight integrity. Independently verified
  • Standard burst pressure Pstat 0.1 bar
  • Max. permitted operating pressure 50 % of Pstat
  • Temperature– 40 to + 180 °C (– 40 to + 356 °F)
  • Material Stainless steel Gasket material FDA approved silicon gasket
  • Tolerance ± 20 % at standard burst pressure
  • Process Pulsating/non-pulsating
  • Standard vacuum resistance 50 % of set pressure at  non-pulsating processes
  • Recommended torque for M10 screws 20 Nm