Rentals
VIG Industries, Inc. offers several models of Hydrocarbon Analyzers to rent for VIG Model 20 Oven Heated THC Analyzer, VIG Model 20/2 Oven Heated Dual Channel THC Analyzer, VIG Model 200 Non-Methane THC Analyzer, VIG Model 200/1 Methane / Non-Methane (NMHC) Hydrocarbon Analyzer, VIG Model 210 Methane / Ethane / Non-Methane-Ethane (NMEHC) / Total Hydrocarbon Analyzer, Ratfisch Model RS-55 CA Oven Heated THC Analyzer, Ratfisch Model RS-102 CA Spot Heated THC Analyzer.
VIG Model 20 Oven Heated THC Analyzer
The VIG Industries, Inc. Model 20 is a microprocessor based, oven heated total hydrocarbon analyzer designed for high accuracy, sensitivity and stability. The Model 20 is designed to continuously measure one point.
The Model 20 utilizes a flame ionization detector (FID). The FID, sample filter, all sample lines, solenoid valves, pump head, capillaries, and other components that come in contact with the sample are maintained in a temperature-controlled heated oven to prevent condensation, and to provide repeatable, reliable performance in the analysis of a wide varieties of hydrocarbon concentrations in gaseous mixtures or in ambient air.
VIG Model 20/2 Oven Heated Dual Channel THC Analyzer
The VIG Industries, Inc. Model 20/2 is a microprocessor based, oven heated total hydrocarbon analyzer for high accuracy, sensitivity and stability. The Model 20/2 is designed to continuously measure two points.
The Model 20/2 utilizes two flame ionization detectors (FID). The flame ionization detectors, sample filters, all sample lines, solenoid valves, pump heads, capillaries, and other components that come in contact with the samples are maintained in a temperature-controlled heated oven to prevent condensation, and to provide repeatable, reliable performance in the analysis of a wide varieties of hydrocarbon concentrations in gaseous mixtures or in ambient air.
VIG Model 200 Non-Methane THC Analyzer
The VIG Industries, Inc. Model-200 is a microprocessor based, oven heated methane / non methane / total hydrocarbon gas analyzer designed for high accuracy, sensitivity and stability. The Model-200 uses two independent flame ionization detectors (FID), one to measure total hydrocarbons and the second coupled with a GC (gas chromatography) column for the separation of the methane and non methane components.
A sample is fed to the analyzer via an internal heated pump to the first FID for a continuous real time total hydrocarbon reading. A portion of the sample is trapped and pushed through a GC column to separate the methane component and then to the second FID. Any remaining sample in the column is back flushed through the column to obtain the non methane component.
The detectors, pump head, capillaries, sample filter, all sample lines, GC column, solenoid valves and all other components that come in contact with the sample through analysis are maintained in a temperature controlled oven to prevent condensation, and to provide repeatable, reliable performance in the analysis of a wide variety of hydrocarbon concentrations in gaseous mixtures or in ambient air.
VIG Model 200/1 Methane / Non-Methane (NMHC) Hydrocarbon Analyzer
The VIG Industries, Inc. Model 200/1 is a microprocessor based, oven heated methane / non methane (NMHC) hydrocarbon analyzer for high accuracy, sensitivity and stability. The Model 200/1 measures methane and non methane hydrocarbons at preset intervals. The VIG Model 200/1 uses one(1) Flame Ionization Detector (FID) to obtain methane and non-methane hydrocarbon readings. A sample is fed to the analyzer via an internal heated pump. After the sample reaches the analyzer, a portion of the sample is trapped and fed through a GC (gas chromatography) column to separate the methane from the total and is fed to the FID detector for analysis. As soon as the methane is read, the remaining sample is back flushed through the GC column and fed to the FID detector for analysis of the non-methane component. The LCD display indicates the amount of methane and non-methane hydrocarbons.
The Model 200/1 utilizes one flame ionization detector (FID). The detector, all sample lines, GC column and all solenoid valves that come in contact with the sample are maintained in a controlled, heated oven to prevent condensation, and to provide reliable performance in the analysis of concentrations of wide varieties of hydrocarbons in gaseous mixtures and in ambient air.
VIG Model 210 Methane / Ethane / Non-Methane-Ethane (NMEHC) / Total Hydrocarbon Analyzer
The VIG Industries, Inc. Model 210 is a microprocessor based, oven heated methane / ethane / non methane-ethane (NMEHC) total hydrocarbon analyzer for high accuracy, sensitivity and stability. The Model 210 measures methane, ethane, non methane-ethane hydrocarbons at preset intervals and continuously measures total hydrocarbons in real time. The Model 210 uses two (2) Flame Ionization Detectors (FID). One FID is used to obtain methane, ethane and non methane ethane hydrocarbon readings. The second FID is used to continuously measure total hydrocarbons. A sample is fed to the analyzer via an internal heated pump. After the sample reaches the analyzer it is fed to the first FID to measure total hydrocarbons. A small portion of the sample is trapped and fed through a GC (gas chromatography) column to separate the methane and ethane from the total and is fed to the second FID detector for analysis. As soon as the methane and ethane components are read, the remaining sample is back flushed through the column and fed to the FID detector for analysis of the non methane ethane component. The LCD display indicates the amount of methane, ethane, residual (non methane ethane) and total hydrocarbons.
The Model 210 utilizes two flame ionization detectors (FID). The detectors, all sample lines, GC column and all solenoid valves that come in contact with the sample are maintained in a controlled, heated oven to prevent condensation, and to provide reliable performance in the analysis of concentrations of wide varieties of hydrocarbons in gaseous mixtures and in ambient air.