RosemountModel 3051S -Thermal Range Expander

SHARE

This seal system measures level and pressure in extreme temperature conditions while improving response time and eliminating heat tracing.

Most popular related searches

What if you could...

  • Easily instrument high temperature processes?
  • Improve response time in extreme temperature applications?
  • Simplify installation and reduce cost?

Easily instrument high temperature processes

  • Expand direct-mount capabilities for temperatures up to 410°C (770°F)
  • Avoid the headaches of additional impulse piping for cooling

Improve response time in extreme temperature applications

  • Prevent DP level capillary systems from becoming unresponsive
  • Enhance response time by 46% over single fill fluid systems
  • Measure reliably at ambient temperatures down to -75°C (-103°F) without the need for heat traced capillary systems

Simplify installation and reduce cost

  • Eliminate heat tracing and routine maintenance costs
  • Remove impulse piping and decrease installed cost

How it Works…

The Rosemount Thermal Range Expander is a seal system that uses two different fill fluids to extend the operating temperature range of the system.

A high temperature fill fluid, which is next to the hot process, is kept warm enough to stay responsive. A second fill fluid, located on the other side of the intermediate diaphragm, operates over a wide ambient temperature range. The Thermal Range Expander can operate in ambient temperatures as low as -75°C (-103°F), and process temperatures up to 410°C (770°F). This improves response time up to 46% and eliminates the need for mechanical heat tracing.

Expand Capabilities with Rosemount Remote Seals

  • Available in 6 remote seal configurations:
    • Flush Flanged (FF)
    • Remote Flanged (RF)
    • Extended Flanged (EF)
    • Remote Threaded (RT)
    • Flush Flanged Ring Type Joint (FC)
    • Ring Type Joint (RC)
  • Install in challenging applications:
    • High temperature processes
    • Corrosive mediums
  • Eliminate issues with impulse piping:
  • Plugging
  • Leaking
  • Freezing

Specifications

  • Measurement Type:Differential, gage, or absolute pressure measurement
  • Product Configurations:Single Remote Seal Configurations: Direct or Remote Mount Styles
  • Dual Remote Seal Configurations: ERS System, Tuned-System Assemblies, or Balanced System
  • Output:4-20mA HART™, FOUNDATION™ fieldbus, WirelessHART™
  • Reference Accuracy:Up to 0.055% of Span
  • Rangedown:150:1
  • Warranty:15-year
  • Complete Specifications (PDF @ 7500Kb)