MultiVap - Model 8 -Sample Concentrators
FromLabTech S.r.l.
The LabTech MultiVap 8 system increases the capacity and sample throughput in laboratories and maintains quality and low cost. With this system it is possible to evaporate to solid state or concentrate into a fixed end-point volume. A compact solution compared to conventional rotary evaporators, with the possibility to be used outside the fume hood thanks to the integrated vapor evacuation system.
Most popular related searches
organics analysis
rotary evaporator
evaporation rate
nitrogen purging
sample concentration
blowdown evaporation
sample cup
safety product
analytical chemistry
fume hood
Concentrators (aka nitrogen evaporators or nitrogen blowdown concentrators) are a valid alternative to rotary evaporation mainly in case of small volumes (under 50 mL) and a large quantity of samples.
Safety, productivity, flexibility and reliability
Concentrators accelerate the evaporation by decreasing the partial vapor pressure of the solvent just above the surface of the liquid. Blowdown evaporators use a jet of gas to continually force off the layer of air that is saturated with vapor. By immediately removing molecules that enter the vapor state, the molecules do not have a chance to return to the liquid, which increases the evaporation rate. As said blowdown technique is very useful for small sample volumes because with larger samples nitrogen blowdown will take longer and semi-volatile compounds may be lost. Since the samples are immersed in a water bath, with programmable temperatures up to 100°C, the evaporation is further accelerated. LabTech offers 4 models, 3 of them automated and one manual, hosting different tube sizes to satisfy multiple needs.
9 good reasons to choose LabTech Concentrators
Advanced solutions and features
Enhanced productivity
Automatic adjustment of nitrogen needle according to the sample volume reduction
Precision, repeatability and gas saving
Visible concentration process
Peace of mind
Vortex nitrogen purge
Provides high speed evaporation
Sample cups do not need to be handled
Time saving and error proof
Automatic detection of the liquid endpoint
Error proof and unattended operations
10, 50 & 200 mL concentration cups can be accommodated
Flexibility and time saving
Cups can go directly to the liquid handler of GPC/SPE
Time saving
Excellent price/performance ratio
A solution for any budget
- Chemistry
- Environmental organic analysis
- Food
- Forensics
- Geochemistry
- Organic analysis
- Organic analytical chemistry
- Petroleum analysis