Secutron - Model MR-2312-DDR -Twelve Zone Conventional Fire Alarm Control Panel
The MR-2312-LDR is equipped with twelve Class “B” (Style “B”) initiating circuits and four Class “B” (Style “Y”) indicating circuits rated @ 1.7 Amps maximum. (Total of 5 Amps). Two MR-2300-A Six Initiating Circuit Class “A” Converter Modules may be used for Class “A” (Style “D”) wiring of the initiating circuits. One MR-2300- NC4 Four Indicating Circuit Class “A” Converter Module may be used for Class “A” (Style “Z”) wiring of the indicating circuits. The MR-2312-LDR is configurable by the keypad (using the CFG-300 Configuration Tool) for onsite programming or by a PC for both onsite and remote programming. The MR-2312-LDR has a built-in UDACT/Digital Communicator and the cabinet will support up to 12 AH batteries. The panel can be semi-flush mounted with the optional MR-2312-FT trim ring.
Comes With
- LCD
- 12 Initiating Class B (Style B)
- 4 Indicating Circuits(1.7 Amps) Class B (Style Y)
- 2 Line UDACT Digital Communicator & Modem
- Supports Multiplexed Annunciation & Smart Relays
- Alarm & Event Logs
- 5 Amp Power Supply (Signal & Aux Supply)
- Front Panel, Laptop Configurative or Remote Dial Up
- Red Door and Black Enclosure
- Listed to UL 864, 9th edition
- Available in six and twelve zone models
- Available in LED and LCD Display configurations
- LCD Display versions are equipped with a 2 line by 20 character back-lit LCD display and numerical keypad
- Integrated UDACT/Digital Communicator on select models
- Front panel and PC programmable
- LED Display versions are front panel (using CFG-300 configuration tool) and PC programmable
- Remote upload/download capabilities
- Base panel is equipped with Class “B” (Style “B”) initiating circuits which may be configured as Class “A” (Style “D”) using a Class “A” converter module
- Initiating circuits may be configured as Alarm, Verified Alarm, Waterflow Alarm, Sprinkler Alarm, Latching or Non-Latching Supervisory, Monitor and Trouble-Only
- Base panel is equipped with Class “B” (Style “Y”) indicating circuits which may be configured as Class “A” (Style “Z”) using a Class “A” signal converter module
- Audible signals may be configured for Steady, Temporal Code, California Code and March Time
- Indicating Circuits may be configured as Silenceable or Non-Silenceable for both signals and strobes
- Built-in sync protocols for the following strobe manufacturers: Mircom, Amseco, System Sensor, Gentex, Faraday and Wheelock
- Relay contacts for Common Alarm, Auxiliary/Alarm (Disconnectable), Common Supervisory and Common Trouble
- Configurable Signal Silence Inhibit, Auto Signal Silence and One-Man Walk Test
- Subsequent Alarm, Supervisory, and Trouble operation
- RS-485 Interface for Remote LED Annunciators, LCD Annunciators and Remote Smart Relay Modules
- Two event history logs comprised of a 200 event alarm log for alarm related events and a 200 event general log for all other events
- 5 Amp Power Supply
- Optional modules for additional internal relay circuits and City Tie/Polarity Reversal
- Optional trim rings for semi-flush mounting