Generex Systems Gmbh

Sensormanager

SHARE

Control unit for all types of sensors and actuators, Compatible with the CS141 series, Can be configured remotely, Alerts via email, SMS and network notifications.

Most popular related searches

The SENSORMANAGER is not a stand-alone unit, but rather an add-on module for the CS141 WEBMANAGER with which the scope of features can be vastly expanded.
The SENSORMANAGER allows for the connection of analog and digital sensors for strategic room surveillance. Since the interface is open, the type of sensor is irrelevant, so you can connect any type of sensor:

  • Gas, water, fluids, acid
  • Glass breakage
  • Motion sensors, light barriers
  • Pressure sensors

The digital inputs and outputs can also be used to directly connect to secondary systems to, for instance, activate an automatic emergency ventilation system, sprinkler systems or directly interact with other systems.
Thus, the CS141, using the SENSORMANAGER, can automatically execute the emergency ventilation in the event of nitrogen accumulation and inform a directly superordinate reporting system of the situation and simultaneously output the status via SNMP, Modbus, BACnet or remote Syslog.


Collective faults and escalation levels can also be generated via the sensor matrix:
If, for instance, a concerning level of nitrogen is in the air and the emergency ventilation does not respond within 2 minutes, an acoustic and visual alarm will be automatically activated.
The digital and analog inputs can be linked logically in any manner so the same sensors trigger an alarm behavior in a variety of constellations.


  • 8 analog inputs to monitor temperature, humidity and many other types of sensors
  • 4 digital inputs for alarm sensors for, e.g. smoke, fire, water, etc.
  • 4 digital outputs for optical and visual alarm transmitters
The SENSORMANAGER is available in the following model variants:
  • As an add-on module for the CS141.
  • As an add-on module for the UPSMan software to connect to a computer.
  • As a special RFC1628 add-on for easy integration into SNMP environments.
  • Enhancement of the CS141 series

  • For monitoring and administration of multiple sensors

  • Support for more than 1400 UPS models

  • For individual configurations of automatic alarm response

  • User-notification via email, SMS, network messages

  • Status reports and event histories

  • Data analysis and visualization

  • Scheduling of standard tasks

  • Includes warning treshhold and EVENT MATRIX configuration to use a AND / OR logic for programming of your EVENTS and alarms

  • 8 analog inputs: 0-10V (optional: 0-20mA)

  • 4 digital inputs: 0-48V

  • 4 digital outputs: 500mA

  • RS-232 serial interface: 1 output, Sub D9 (cables included)

  • Power supply: 9-24VDC wide range, 500mA

  • Operating temperature: 0-40°C, 10-80%, not condensated

  • CE certificated