Shimadzu - Model Prominence HPLC -High-Performance Liquid Chromatograph
The Shimadzu Prominence high-performance liquid chromatograph (HPLC) achieves an exceptional level of performance, reliability, and economy. Prominence HPLC covers a wide variety of flow rates and application goals. Prominence is expandable to support a diverse range of applications: Multiple solvent delivery options, a broad range of flows, and isocratic or gradient elution. Numerous detector options to cover a range of sample chemistries. Expandable valving options from simple to complex flow paths. Covering a broad range of analyses from analytical to semi-preparative, reversed phase, normal phase, Gel Permeation Chromatography (GPC) and Ion Chromatography (IC).
CBM Web Browsing
Ability to monitor and control you LC system over a network.
Unrivaled Analytical Solvent Delivery Units
World class pumps with unrivaled performance from semi-micro-flow rates (below 50 uL/min) up to semi-preparative flow rates (10 mL/min).
Pulse-free solvent delivery, essential for high quality data acquisition.
High accuracy gradient formation by low-pressure gradient elution or a binary high-pressure gradient elution.
Needle-in-Flow Path Autosampler with Increased Throughput
Flow through the needle reduces sample carryover to an absolute minimum.
The high-performance measuring pump provides precision and accuracy for sample injections of even the smallest volumes (1 μL or less).
Increased sample capacity with full automation and high speed injections.
Large Capacity Column Oven with Precision Temperature Control
Oven temperature is calibrated at two different points to ensure a high degree of accuracy.
Large column compartment can comfortably hold up to three 300 mm columns, two flow control valves, two manual injectors, and a gradient mixer.

Autosampler
SIL-20A/C HT
- Injection method: Needle-in-flowpath
- Injection volume accuracy: ±1% (at 100 μL injection, n = 10)
- Injection volume range: 0.1 to 100 μL (Option: 0.1 to 50 μL, 1 to 500 μL, 1 to 2,000 μL)
- Injection volume reproducibility: RSD: 0.3% maximum (at 10 μL injection)
- Samples capacity: Sample plate: 175 (1 mL), 105 (1.5 mL), 50 (4 mL), 2 (MTP/DWP plates), Control plate: 10 (1.5 mL)
- Sample cooler: Block cooling/heating, used together with defumidifying function 4 to 40°C
- *No sampler cooler included in SIL-20AHT model
Oven
CTO-20A/C
- Oven Capacity: W220 × D95 × H365 mm
- Temperature control range: Room temperature ± 10 to 85°C, Setting range 4 to 85°C
UV Detector
SPD-20AV
- Wavelength Range: 190 to 900 nm (with optional tungsten lamp)
- Noise level: ±2.5 × 10?6 AU, (250 nm, Specified condition)
- Flow cell: 12 μL (10 mm), 12 MPa
- Option cell: High-Sensitivity: 8 μL (10 mm)
- Semi-micro: 2.5 μL (5mm)
PDA Detector
SPD-M20A
- Wavelength Range: 190 to 800 nm
- Noise level: ±6 × 10?6 AU, (250 nm, Specified condition)
- Flow cell: 10 μL (10 mm), 8 MPa
- Option cell: High-Sensitivity: 8 μL (10 mm)