SY02 is a granular iron hydroxide adsorbent with a large specific surface area of 300 m²/g. It can adsorb inorganic arsenic As(?/?), phosphate P(?), as well as other pollutants such as lead, copper, zinc, vanadium, antimony, radium, uranium, and hydrogen sulfide in water. For detailed performance data and influencing factors, see our technical guide.
It is mainly applicable to arsenic removal from drinking water and advanced adsorption and removal of phosphate radicals at the end of wastewater treatment. When the pH value of water is 6.0-7.2, the adsorption capacity of SY02 reaches its peak.
- Indicator Name: Indicator
- Composition: Fe(OH)₃ / β-FeOOH
- Appearance: Black Irregular Granules
- Action Mechanism: Adsorption
- Bulk Density (g/ml): 1.05-1.25
- Bulk Density (g/ml): 6-14(As)
- Particle Size Range (%): 0.3~3.0mm(>90%)
- Indicator Name: Reference Value
- Filter Bed Height (mm): > 800mm
- Empty Bed Contact Time (min): 3-6min
- Operating Flow Rate (BV/h): 8-20
- Applicable pH Range: 5-9
- Regeneration (Phosphate): 1-5% NaOH solution slow washing/soaking for 80min
- Operating Temperature (℃): 5-40
-
During use, repeated loading and unloading of the filter media should be avoided as much as possible to prevent uneven filter media bed leading to channeling.
-
For short-term shutdown
the filter media should be disinfected, cleaned thoroughly and then soaked in clean water. -
For long-term shutdown or when the room temperature is lower than 5℃ in winter, the filter media should be soaked in 1-5% sodium hydroxide aqueous solution to prevent bacterial growth and freezing.
-
The water entering the filter tank must undergo necessary pretreatment filtration to remove solid impurities, reduce SS (Suspended Solids) and prevent pore blockage which affects the adsorption effect of the filter media.
It should be stored in a cool and dark place. Prevent the filter media from freezing or overheating: the general storage environment temperature of the filter media is 5 ~ 40℃. The storage time of unused filter media should not be too long, generally not exceeding 1 year. If the storage period is exceeded, it can be used continuously after passing the re-inspection.