AirTrak is a thermal mass flow meter specifically designed to measure engine air intake mass flow rate. The instrument is: Ideal for the toughest transient test cycles where flow excursion can approach 10:1 within less than two seconds. Uses extremely sensitive, 200-millisecond response-time thermal insertion sensor. A flexible solution for constrained piping environments commonly found in today’s engine and vehicle test facilities with integral laminar flow conditioning inside the flow body and wide 15:1 turndown.
Most popular related searches
mass flow metering
mass flow meter
mass flow
flow meter
mass flow monitoring
air intake
thermal mass flow meter
air mass flow meter
gas flow meter
gas flow monitoring
- Ensures accurate and repeatable engine air intake mass flow measurements
- Increase efficiency with fast response time within 200 milliseconds to changes in flow
- High performance in constrained piping with flow profile conditioning elements inside the flow body
- Increase flexibility with wide turndown range
Operating Principal: Thermal dispersion technology for direct mass flow measurement featuring no pressure or temperature compensation needed, no moving parts, low pressure drop, high turndown. Watch the video...
- Specifically designed for engine intake air mass flow rate applications
- Outstanding 15:1 turndown for high accuracy at low idle conditions
- Smart electronics permit field adjustment of critical flow meter settings
- Programmable pulse output for remote totalization
- Minimal flow blockage and low pressure drop
- Field flow-range adjustment, meter validation and diagnostics
- Program transmitter via RS-232 using free user software or with three push-button display interface
- Sierra`s state-of-the-art ISO 9000 calibration facility matches each application for best accuracy
- Flow-range adjustment, and validation and diagnostics
- Field Validation/Configuration to assure operating performance
- Flow totalizer and alarms
- 2 x 12 backlit LCD display totalizer values
- Remote enclosure mounting available
- No moving parts
- Free computer interface software: Download now
- Measure engine intake air and all clean inert gases
- Accuracy: +/- 1% of full scale
- Repeatability of +/- 0.2% of full scale
- Response time 200 milliseconds to achieve 63% of final value
- Pipe sizes from 1.5" (3.8cm) up to 8" (20.3cm)
- Flow range maximum 30,337 lb/hr (13,779 kg/hr)
- 15:1 turndown
- Temperature:
- Gas: -40°F to 176°F (-40°C to 80°C)
- Ambient: -40°F to 120°F (-40°C to 50°C)
- Power supply 15 to 18 VDC (regulated), 625 mA draw maximum
- Output signals: Linear 0–5 VDC and 4-20 mA
- User definable pulse output for totalized flow
- Digital communications solutions include: Modbus RTU
- Enclosure NEMA 4X (IP65); remote electronics mounting available
- CE approved