LGCModel CRM -Single-Element Aqueous

SHARE

Intended Use: This solution is intended for use as a certified reference material or calibration standard for inductively coupled plasma optical emission spectroscopy (ICP-OES), inductively coupled plasma mass spectrometiy (ICP-MS), or alternative techniques, such as and flame or furnace atomic absorption spectroscopy (AA or GFM).

Most popular related searches

Certification & Traceability: VHG CRMs are manufactured and certified under a quality management system that is accredited to ISO 9001, ISO Guide 34 and ISO/IEC 17025. This CRM was prepared to the certified concentrations shown above by gravimetric methods using single-element concentrates that were certified using the "High Performance ICP-OES` protocol developed by NIST and are directly traceable to the NIST SRMs listed below. This solution was stabilized using high purity hydrochloric acid (HCI) and diluted with filtered (0.22pm), 18 M-ohm deionized water. The balances used in the preparation of VHG CRMs are calibrated regularly with traceability to NIST All volumetric dilutions are performed in Class A calibrated glassware. The certified concentrations were determined by VHG Labs based upon gravimetnc procedures. Secondary verification of the certified concentrations was performed by VHG Labs using ICP-OES that was calibrated and/or referenced against NIST SRMs: 3121. The uncertainty associated with each certified concentration represents the expanded uncertainty at the 95% confidence level using a coverage factor of k=2.

Instructions for Use: We recommend that the solution be thoroughly mixed by repeated shaking or swirling of the bottle immediately prior to use To achieve the highest accuracy the analyst should: (1) use only pre-cleaned containers and transferware, (2) not pipette directly from the CRM`s original container, (3) use a minimum sub-sample size of 500pL, (4) make dilutions using calibrated balances or certified volumetric class A flasks and pipettes, (5) dilute with the same matrix as the original CRM, and (6) never pour used product back into the original container. The solution should be kept tightly capped and stored under normal laboratory conditions. Do not freeze, heat, or expose to direct sunlight. Minimize exposure to moisture or high humidity.

Period of Validity: VHG ensures the accuracy of this solution for 12 Months from the Certification date shown below, provided the instructions for use are followed. During the period of validity, the purchaser will be notified if this product is recalled due to any significant changes in the stability of the solution.