GDS Technologies Ltd.
  1. Companies
  2. GDS Technologies Ltd.
  3. Products
  4. GDS - Model 100 - Single Point Gas ...

GDSModel 100 -Single Point Gas Alarm

SHARE

A fixed single point alarm unit that meets the requirements for economic and reliable monitoring of gas levels in a wide range of environments from commercial premises through to heavy industrial applications which may require  hazardous area sensing. Typical monitor locations are - public buildings, boiler plant rooms, swimming pools, water treatment works, H&V control systems, manufacturing and process plants.

Most popular related searches
  • Flammable, Oxygen, Refrigerant and Toxic gases
  • Wall or panel mount
  • Two alarm stages + relays
  • Internal or remote sensor
  • Compact size
  • Low power consumption
  • 4-20mA analogue output
  • Sealed to IP65 rating
  • Extensive fault detection circuitry
  • Digital Display

  • Measuring Range:
    • Combustible Gas - LEL, % Vol, ppm
    • Toxic Gas - ppm, % Vol
    • Oxygen - % vol - Depletion or Enrichment
    • Any 4~20mA input signal
  • Indicators:
    • Digital Display 3 1/2 Digit
    • Power - Green L.E.D.
    • Switch on delay power indicator flashing - 45 secs
    • Alarms Lo-Hi Red L.E.Ds
    • Fault Amber L.E.D.
    • System Test - Alarm L.E.D.s flashing
    • Alarm relay inhibit - Fault L.E.D. on
  • Audible Alarm : Low, High and Fault Alarms
  • Power Supply : 230/115v AC 50/60 Hz or 24vDC The two voltages may be utilised simultaneously - standby battery
  • Power Consumption : 4 watts - full alarm
  • Outputs :
    • Low, High and Fault alarm relays - SPCO normally de-engerised - energised option
    • Low gas alarm relay SPCO normally energised - de-energised option
    • latched or unlatched
    • Fault relay SPCO normally de-energised - energised option
    • All contacts rated 5A - 230v AC
    • 4-20mA/1-5v
    • Output 24vDC @ 100mA max - auxiliary equipment (non inductive)
  • Alarm Settings :
    • Digital setting (fully adjustable between zero and full scale)
    • Delay to alarm options - 10/30 seconds, 10 minutes
  • Sensor Inputs :
    • Bridge type 3 wire detector mv (Catalytic)
    • 4-20mA (electrochemical/infrared)
  • Sensor Cable : 3 core 1.5mm2 screened 1.5km
  • Miscellaneous :
    • Operating temperature -10 to +50°C
    • Storage temperature -10 to 65°C
    • Alarm relay inhibit during calibration
    • Sounder Inhibit
    • System function test switch
    • Dimensions L200mm H 120mm D 58mm
    • Weight 0.8kg
    • Protection IP65
    • Field Terminals - screw type 2.5mm
    • Cable entry - top, bottom, sides, rear