A fixed single point alarm unit that meets the requirements for economic and reliable monitoring of gas levels in a wide range of environments from commercial premises through to heavy industrial applications which may require hazardous area sensing. Typical monitor locations are - public buildings, boiler plant rooms, swimming pools, water treatment works, H&V control systems, manufacturing and process plants.
Most popular related searches
swimming pool water treatment
gas alarm
swimming pool water
hazardous area monitoring
hazardous area
swimming pool
infrared sensor
remote sensor
toxic gas
water treatment
- Flammable, Oxygen, Refrigerant and Toxic gases
- Wall or panel mount
- Two alarm stages + relays
- Internal or remote sensor
- Compact size
- Low power consumption
- 4-20mA analogue output
- Sealed to IP65 rating
- Extensive fault detection circuitry
- Digital Display
- Measuring Range:
- Combustible Gas - LEL, % Vol, ppm
- Toxic Gas - ppm, % Vol
- Oxygen - % vol - Depletion or Enrichment
- Any 4~20mA input signal
- Indicators:
- Digital Display 3 1/2 Digit
- Power - Green L.E.D.
- Switch on delay power indicator flashing - 45 secs
- Alarms Lo-Hi Red L.E.Ds
- Fault Amber L.E.D.
- System Test - Alarm L.E.D.s flashing
- Alarm relay inhibit - Fault L.E.D. on
- Audible Alarm : Low, High and Fault Alarms
- Power Supply : 230/115v AC 50/60 Hz or 24vDC The two voltages may be utilised simultaneously - standby battery
- Power Consumption : 4 watts - full alarm
- Outputs :
- Low, High and Fault alarm relays - SPCO normally de-engerised - energised option
- Low gas alarm relay SPCO normally energised - de-energised option
- latched or unlatched
- Fault relay SPCO normally de-energised - energised option
- All contacts rated 5A - 230v AC
- 4-20mA/1-5v
- Output 24vDC @ 100mA max - auxiliary equipment (non inductive)
- Alarm Settings :
- Digital setting (fully adjustable between zero and full scale)
- Delay to alarm options - 10/30 seconds, 10 minutes
- Sensor Inputs :
- Bridge type 3 wire detector mv (Catalytic)
- 4-20mA (electrochemical/infrared)
- Sensor Cable : 3 core 1.5mm2 screened 1.5km
- Miscellaneous :
- Operating temperature -10 to +50°C
- Storage temperature -10 to 65°C
- Alarm relay inhibit during calibration
- Sounder Inhibit
- System function test switch
- Dimensions L200mm H 120mm D 58mm
- Weight 0.8kg
- Protection IP65
- Field Terminals - screw type 2.5mm
- Cable entry - top, bottom, sides, rear