E-Mon
Class - Model 5000 -Smart Meter with Dual Protocol Communications
FromE-Mon
0-2 volt output split-core current sensors allow for enhanced safety and accurate remote mounting of sensors up to 500 feet from meter without power interruption. (Optional solid-core current sensors available in 100 & 200 amp.). Onboard diagnostics and verification system.
Most popular related searches
current sensor
smart meter
automatic meter reading
stainless steel enclosure
polycarbonate enclosure
meter reading
remote sensor
water meter input
laboratory testing
water metering
- Advanced 4-line display showing:
- - kWh
- - kWh/Demand (with peak date and time)
- - Power factor per Phase
- - Real-time load in kW
- - Amps per Phase
- - Volts per Phase
- On-board set-up option for:
- - IP Address
- - Meter date/time
- - ID codes for EZ7, Modbus and BACnet
- 0-2 volt output split-core current sensors allow for enhanced safety and accurate remote mounting of sensors up to 500 feet from meter without power interruption. (Optional solid-core current sensors available in 100 & 200 amp.)
- Onboard diagnostics and verification system.
- Two pulse outputs & two external meter inputs (water, gas, BTU, etc.) (Channels 5 & 6 available via E-Mon Energy only)
- Phase loss alarm. (N.O. Contact)
- Built-in RS-485 communications capability supports up to 52 Class 3200, 3400, 5000 meters and/or IDR interval recorders(or combinations not to exceed 52 devices per channel). 00
- Cabling can be either daisy-chain or star configuration, 3-conductor, 18-22 AWG, up to 4,000 feet cable total per channel.
- Built-In RS-485 & Ethernet Communications. Optional telephone modem available.
- Protocols
- - EZ7
- - Modbus RTU
- - Modbus TCP/IP
- - BACnet MS/TP*
- - BACnet IP*
- - LonWorks FT-10 (Twisted Pair)*
- Records kWh and kVARh delivered, kWh and kVARh received in first 4 channels. Data stored in 15-minute intervals for up to 72 days or 5-minute intervals for up to 24 days. Maintains interval data storage in a first-in, first-out format.
- Compatible with E-Mon Energy software via EZ7 protocol for automatic meter reading, billing and profiling of interval energy data.
- Meter is designed for use on both 3-phase, 3-wire (delta) and 3-phase, 4-wire (wye) circuits.
- Outdoor NEMA 4X polycarbonate enclosure (standard) with padlocking hasp & mounting flanges for indoor/outdoor installation (stand alone) with one 1 1/16"" KO on bottom of enclosure.
- Optional Enclosure: Industrial grade JIC steel enclosure with padlocking hasp and mounting flanges for indoor installation (stand alone). Knockouts: 1 1/16"" (3/4"" cond.) on bottom and 7/8"" (1/2"" cond.) on top of enclosure.
- UL/CUL Listed. Certified by independent test lab to ANSI C12.20 national accuracy standards. (+/- 0.2% from 1% to 100% of rated load.)
- Compatible with both 50 Hz and 60 Hz applications.
- CE Mark Approved.
- Meter meets or exceeds MID accuracy standards.
- BACnet protocol is BTL certified. LonWorks protocol is LonMark certified.
- MV-90 Compatible (EZ7 only).
120/208-240V, 3 Phase(Supplied with (3) Split-Core Current Sensors)
- E50-208100-R*KIT (100 Amp)
- E50-208200-R*KIT (200 Amp)
- E50-208400-R*KIT (400 Amp)
- E50-208800-R*KIT (800 Amp)
- E50-2081600R*KIT (1600 Amp)
- E50-2083200R*KIT (3200 Amp)
220/380V, 230/400V, 240/415V, 3 Phase(Supplied with (3) Split-Core Current Sensors)
- E50-400100-R*KIT (100 Amp)
- E50-400200-R*KIT (200 Amp)
- E50-400400-R*KIT (400 Amp)
- E50-400800-R*KIT (800 Amp)
- E50-4001600R*KIT (1600 Amp)
- E50-4003200R*KIT (3200 Amp)
277/480V, 3 Phase(Supplied with (3) Split-Core Current Sensors)
- E50-480100-R*KIT (100 Amp)
- E50-480200-R*KIT (200 Amp)
- E50-480400-R*KIT (400 Amp)
- E50-480800-R*KIT (800 Amp)
- E50-4801600R*KIT (1600 Amp)
- E50-4803200R*KIT (3200 Amp)
347/600V, 3 Phase, 4 W (Wye Config.)(Supplied with (3) Split-Core Current Sensors)
- E50-600100-R*KIT (100 Amp)
- E50-600200-R*KIT (200 Amp)
- E50-600400-R*KIT (400 Amp)
- E50-600800-R*KIT (800 Amp)
- E50-6001600R*KIT (1600 Amp)
- E50-6003200R*KIT (3200 Amp)
