C-Air - Model HSE 261 -Smoke Clearance Testing System for Spray Booths
HSE 261 recommends that a smoke clearance testing is carrid out 14 mothly along with yor LEV COSHH test (we also offer this service). Using professional smoke machines, we can carry out the smoke test efficiently and supply you with the pass certificates.
Smoke is most likely to linger and form eddies close to all the walls of a downdraft spray booth; in a room, the smoke will mix with the air and dilute evenly.
By disabling the extraction before filling the room with smoke a maximum clearance time is measured. As the extraction is usually running during normal spraying operations, the clearance time may be less than this but as a safety margin, it is important that the maximum time is observed.
For a no obligation quotation for Smoke or LEV testing then please contact us.
The Smoke Testing Process:
- Extraction off – Lights on
- Smoke machine on
- 2 minutes…
- Smoke machine off – White out
- Start extraction & timer
- Inspect seals & ducting for leakage
- Smoke clear – Test complete
- Certicate for display