PHENIX Technologies Inc
  1. Companies
  2. PHENIX Technologies Inc
  3. Products
  4. Phenix Technologies - Model PD3U - ...

Phenix TechnologiesModel PD3U -Spectrum Analyzer, Partial Discharge Detector, and RIV Meter

SHARE

Its benefits include frequency spectrum analysis, 4-channel measurement capability, and center frequency adjustable from 10 kHz – 10 MHz in 10 kHz steps.

Most popular related searches
  • Compact design
  • Easy to use
  • Precise results
  • Stand-alone or computer operated
  • Frequency spectrum analysis
  • 4-channel measurement capability
  • Center frequency is adjustable from 10 kHz – 10 MHz in 10 kHz steps

Partial Discharge Measuring

  • The model PD3U comprises a Spectrum Analyzer, a PD detector, and a RIV meter in one instrument. This combination enables PD measurements even with a large background noise, such as in non-shielded test areas. Observing the frequency spectrum of a significantly noisy PD signal allows the user to select frequency bands with less disturbance resulting in a clearer pattern acquisition.
  • In RIV mode, the instrument has bandwidth of 9 kHz and 270 kHz. When utilizing either the CAL3B or CAL3D calibrator, the range is 400 kHz – 1900 kHz in steps of 100 kHz. Technically, the 4 Channel unit in RIV mode, is a selective µV-meter according to the CISPR weighing curve whereas the repetition rate has a strong impact on the reading.
  • Measurements are according to IEC 60270-2000, IEEEC57.12.90, and RIV measurements are according to NEMA/CISPR regulations and other relevant standards.

Testing Applications

  • Condition evaluation of insulation systems
  • Quality assurance testing in manufacturing plants
  • Routine testing in a variety of applications

Desktop Acquisition and Display Unit

  • Spectrum, Scope and Meter display
  • Selectable bandwidth 9 kHz and 270 kHz
  • Center frequency is adjustable from 10 kHz – 10 MHz in 10 kHz steps
  • MUX4 Multiplexer 4-channel measurement
  • Internal (line 50/60 Hz) and external synchronization (10-500 Hz)
  • Auto-range function
  • Backlit LCD 240 x 128 dots
  • RIV and PD calibration
  • RIV reference input
  • Automatic storage of current settings
  • Universal serial interface (USB, up to 921 kB)
  • AMP IN and REF IN connector
  • REC OUT

Built-in Voltage Measurement

  • Measures the voltages at the external sync input terminal
  • Display of peak; peak/√2, and RMS value
  • Input range 100 Vrms
  • Input impedance: 1 M?

Built-in TTL Gating

  • Triggered Noise Cancellation
  • Software controlled gating from a signal connected to an auxiliary input
  • Gating threshold may be set manually or automatically
  • Includes the built-in logarithmic preamplifier RPA6

Acquisition Unit

  • Input : 100-240 VAC, 50/60 Hz
  • Power : 25 VA
  • Temperature Range : 10°C – 40°C
  • Dimensions : 9 ³/8” (236 mm) W
  • 11½” (295 mm) D
  • 5¼” (133 mm) H
  • Weight : 7 lbs. (3 kgs)

Reference Voltage Input

  • Input Impedance : 100 MΩ / 200 pF
  • Input Voltage : Max. 120 V (rms)
  • Frequency : 10-500 Hz

Partial Discharge Signals

  • Coupling : AC
  • Input Impedance : 50 Ω (without RPA)