Beirens SAS
  1. Companies
  2. Beirens SAS
  3. Products
  4. Beirens - Steel Lining and Lining ...

BeirensSteel Lining and Lining Chimneys

SHARE

Steel lining involves introducing one or more separate welded flues inside an existing smoke flue so as to make the installation workable. This lining replaces the old smoke flue. The main purpose of the lining is to make the smoke flue, no longer meeting the regulations in force in this field, tight to combustion gas.

Most popular related searches
  • Easy to implement
  • Saves money compared with creating a new chimney
  • Keeps the existing structure
  • Effective and long-lasting
  • Adapted to the existing structure

Insulated tightness at chimney head
With a view to making the existing chimney more reliable, we install a watertight plate in stainless steel 1.4404 (316L) to cover the outside of the old flue. This protects the inner wall of the brick flue from acid flowing down in rainwater and ensures natural ventilation.

  • Tightness reading and watertight plate in stainless steel 1.4404 (316L) ensures guidance, free expansion and
    ventilation of the flue
  • Smoke flue insulated with mineral wool, density 80kg/m3, thickness 50mm
  • Chimney termination seal in stainless steel 1.4404 (316L)
  • Stainless steel smoke flue (welded by tight connections) insulated by an air gap (between the brick shell and the
    smoke flue)
  • Condensation collection base
  • Straight base reinforcements
  • Inspection door

  • Lightning conductor system: stainless steel rods comply with local regulations with “crow’s foot” earth connection,
    copper plate outside heat insulation and lightning meters
  • Fall arrest system ladder compliant with NF EN 353-1, fixed hoop ladder with landings or offset flights (height
    between two landings to 6m according to NFE 85-016 and ISO 14122-4, height between 2 platforms, so a single
    section to 8m according to NFE 85-016 and to 10m according to ISO 14122-4). Specific compliance on demand.
  • Inspection platform and work platform compliant with NFE 85-014 or ISO 14122-2. Specific compliance on
    demand.
  • Access door(s) and passage(s)
  • Weighted index measuring point EN 13 284 2
  • Continuous measuring points
  • Internal lighting: connection at the chimney base
  • Aircraft warning day-time marking: with paint red and white stripes
  • Aircraft warning night-time marking: high-intensity duty/standby lamps to be supplied from chimney base
  • Acoustic treatment by beirens: absorptive silencers (bulbs, baffles, absorbent wall), reactive silencers (single
    chamber, double-chamber, wave resonators)
  • Vibration loading treatment: lining damper cushion

BEIRENS offers to undertake:

  • Survey of existing works
  • External and internal inspections, infra-red thermography, UT wall thickness inspection.

Maintenance and refurbishment

  • Repairing of chimney shells, treatment of the concretes, boilerworks, reinforcements in underpinning...
  • Repairing or modification of the accessories, gangways, ladders, coping, lightning protection systems, guy-wires...
  • Aircraft warning day-time and night-time marking.
  • Painting.
  • Repairing of smoke flues, of internal brickwork, steel-lining, SVR lining...
  • Repairing of listed buildings
  • Partial or total demolition of existing stacks