Hunan Sundy Science and Technology Co.,Ltd
- Home
- Companies
- Hunan Sundy Science and Technology ...
- Products
- Sundy - Model SDACM3100 - Bomb ...
Sundy - Model SDACM3100 -Bomb Calorimeter
SDACM3100 can be used to determine the calorific value of solid and liquid combustibles such as coal, coke, petroleum oil, cement black meal, biomass fuels as well as building material. Most cost effective model with reliable results. Analysis time is 15 min.
Most popular related searches
bomb calorimeter
water temperature test
water temperature testing
calorimeter
oxygen water
temperature monitoring
water circulator
water distiller
water distillation
building material testing
Highlights:
- Accurate test result with large water quantity. Difference of jacket water temperature in each test is less than 0.1K.
- Support oxygen bomb air tightness examination, no complicated elevating mechanism and compressor.
- Strong data processing capability, statistics report and printing function; Capable of connecting with network and balance by RS232 interface.
- With exp
Application:
SDACM3100 can be used to determine the calorific value of solid and liquid combustibles such as coal, coke, petroleum oil, cement black meal, biomass fuels as well as building material.
Highlights:
- Accurate test result with large water quantity. Difference of jacket water temperature in each test is less than 0.1K.
- Support oxygen bomb air tightness examination, no complicated elevating mechanism and compressor.
- Strong data processing capability, statistics report and printing function; Capable of connecting with network and balance by RS232 interface.
- With expert diagnostic, self-protection, self-diagnostic function
- Authentic test data, no software modification.
- Analysis Time : 15min
- Temperature Resolution : 0.0001K
- Precision(RSD) : ≤0.15%
- Heat Capacity Stability : ≤0.25% within three months
- System Structure : Benchtop
- Conformance with Standard : ISO 1928, ISO 9831,ISO18125,ASTM D5865, ASTM D240, ASTM D4809, ASTM E711, ASTM D5468,GB/T 213,GB/T 30727, AS 1038.5,BS EN 15400, BIS1350
- Test per Hour : 2~4
- Bomb volume : 282ml
- Calorimeter Type : Isoperibol
- Oxygen Filling : Semi-automatic
- Bomb Washing : Manual
- Max.Bomb pressure : 20Mp
- Bomb Identity : No
- Gas Requirement : 99.5% Oxygen
- Water Requirement : Distilled Water
- Energy Measurement Range : 0~50000J
- Bucket Filling : Automatic
- Constant Volumetric Tank with Temp Control Device : No
- Independent Bucket and Jacket Water System : No
- Stirring Method : Blade
- Power Inverter : No
- Reproducibility based on analysis of 1g Benzoic Acid : 0.15%
- Average Temperature Increase : 2?
- Temperature Measurement : PT1000
- Working Temperatures : ?32?
- Cooling method : Automatic by water circulation
- Network : Yes
- Power : AC 220V(-15% +10%)50/60Hz
- Max.Power : 0.22kW
- Dimension : Main body: 600*500*425
- Main Body Weight : 65kg
- Advance Calculation : No
- Analysis Report : Yes
- Statistics Report : Yes
- System Monitor : Yes