Particle Measuring Systems (PMS)
PMS UltraChem - Model 100 & SLS-1100 -Syringe Liquid Sampler With Particle Counter
The SLS Syringe Sampling System is ideal for applications where precise, small-volume sampling is needed. The system consists of a syringe sampler for either corrosive or non-corrosive liquids, a particle counter for dierent sizing sensitivities, and soware. A convenient naming system identifies the particle counter installed inside the instrument.
Most popular related searches
particle counter
liquid particle counter
liquid sampling
particle sensor
precision particle monitoring
particle sampling
process monitoring
process monitoring system
chemical manufacturing
sample temperature
- Precise particle measurement
- Versatile - select various particle sensors and syringe sizes
- Cost-effective
- Easy-to-use
- Small sample volume - eliminates sample waste
- Proven PMS UltraChem particle sensors
- Menu-driven data collection - 1, 5, 10 and 25 ml
- Wetted materials compatible with corrosive chemicals
- Compact design with on-board particle sensor
- Diverse applications in semiconductor and process chemical manufacturing
- Incoming quality measurement of process chemicals
- Point-of-process monitoring on process tools
- Testing and qualification of chemical components
- Outgoing chemical qualification testing
- Mechanical parts cleanliness testing
- SLS-1100
- Syringe size: 25 ml
- Sampling mode: Vacuum, Batch
- Minimum sample size: 0.4 ml @ 20 ml/min
- Wetted surface materials: Glass, Teflon (all fluoropolymer materials optional)
- Power: 100 - 240 V, 50 - 60 Hz
- Sample volume: Adjustable using soware interface
- External Dimensions (l, w, h): 15 x 9 x 17.1 in (38.1 x 22.0 x 43.4 cm)
- Weight: 42 lb (19.1 kg)
- Environment
- Temperature: 50 – 86 °F (10 – 30 °C)
- Humidity: Non-Condensing
- Indoor use only
- Pollution degree 2
- Over-voltages (transients) Category II
- Ordinary protection (not protected against harmful ingress of moisture)
- Class I equipment (Electrical earth ground from the mains power source to the product input is required for safety purposes)
* Greater than 90% accuracy (less than 10% coincidence loss) at max. recommended concentrations.
** Compatible with hydrofluoric acid sampling.
- SLS instrument label: SLS-1100
- Size range: 100 - 500 nm
- Channels: 100, 200, 300, 500 nm
- Flow rate: 20 ml/min
- Sampled%:
- 30% Monitor mode
- 16% Spectrometer mode
- 13% High-Scatter mode
- Maximum concentration*
- 3,000 particles/ml, Monitor mode
- 9,000 particles/ml, Spectrometer mode
- 15,000 particles/ml, High-Scatter mode
- Zero count: < 50 counts/l
- Maximum pressure: Ambient pressure
- Laser source
- Laser diode
- Class I, complies with US 21 CFR 1040.10 and EN 60825-1.
- Internally an enclosed Class 4 laser is used per EN 60825-1.
- Sample temperature: 50 - 122 °F (10 - 50 °C)
- Wetted surface materials: Sapphire**, Teflon, Kel-F®
- Calibration: Materials used are traceable to National Institute of Standards & Technology (NIST) and/or Japanese Industrial Standards (JIS).
- Soware: SamplerSight