Tan Delta Systems Ltd
TanDelta - Model OQSx-G2 -Real Time Oil Condition Analysis Sensor
Real-time continuous oil condition analysis with integrated intelligent equipment maintenance optimisation analytics. Detects and measures all and any wear and contamination. Any industrial or commercial application – any oil type. Easy to install, the OQSx-G2 continually analyses oil in real-time whilst equipment is in operation and provides an accurate statement of oil condition. Any wear or contamination is instantly detected, measured to an accuracy of 0.001%, and reported.
Most popular related searches
oil condition analysis
oil analysis
contaminated water
real-time analyzer
emissions standard
RoHS compliance
oil analyzer
acid water
acidic water
contaminant detection
- FULL SPECTRUM HOLISTIC (FSH™) - Detects all and any wear and contamination: water, acid, fuel, viscosity, different oil types, carbon, particles etc.
- ABSOLUTE ACCURACY - The FSH technology within our sensor enables it to have a oil quality change sensitivity detection of 0.01% (10ppm) with an accuracy margin of +/-0.5%.
- REAL-TIME - Continuously analyses oil condition on operating equipment and reports oil condition every two seconds.
- ROBUST & RELIABLE - Proven around the world for use in even the most extreme industrial and commercial applications.
- EASY TO INSTALL - Quick and easy to install on any equipment with plug & play integration with any existing data reporting and display systems.
PRODUCT INFORMATION
- Name : Gen II - Oil Quality Sensor
- Product Number : OQSx-G2-1-DD-02-5
PHYSICAL
- Material : Stainless Steel AISI304
- Dimensions : 102mm x 36mm (L x W)
- Weight : 180g
- Connection : 32mm AF Hex Collar
- Torque : 25N m
AVAILABLE THREADS
- Thread : Seal
- 1/2” BSPP : Dowty Type
- 1/2” NPT : n/a
- 7/8” UNF : ‘O’ Ring
- M18 : Dowty Type (Alternative threads available upon request)
CONNECTIONS
- Connector : 6 pin Bulgin 4000 series
ELECTRICAL
- Supply : +9-30 V DC
- Consumption : 0.4w Average
- DATA OUTPUT / INPUT
- Digital Output : RS485, CANbus
- Protocols Supported : Modbus, CanOpen and J1939
- Analog Output : 4-20mA
- OIL QUALITY DETECTION PARAMETERS
- Frequency : Every 2 seconds
- Output : Tan Delta Number (TDN)
- Oil Temperature (°C or °F)
- Accuracy : +/-0.5%
- Elements : All wear and contamination
ENVIRONMENTAL
- Operating Temperature : -40°C (-40°F) to +120°C (+248°F)
- Calibrated Temperature : -20°C (-4°F) to +120°C (+248°F)
- Fluid Temperature : -40°C (-40°F) to +120°C (+248°F)
- Fluid Pressure : up to 70 bar (1015 psi)
- Storage Temperature : -55°C (-67°F) to +150°C (+302°F)
STANDARDS & CERTIFICATION
- Water & Dust : IP68 when connected
- Shock & Vibration : BS EN 60068-2-30 (Test Db - Cyc.Hum.)
- BS EN 60068-2-6 (Test Fc - Sine Vib.)
- BS EN 60068-2-27 (Test Ea - Mech.Shock)
- EMC : EN 61000-6-4:2007 (Generic Emissions Standard for Industrial Environments)
- EN 61000-6-2:2005 (Generic Immunity Standard for Industrial Environments)
- Conformity : CE Marked