NEO Monitors LaserGasModel III OP -TDLS Open Path Gas Detector

SHARE

LaserGas™ III Open Path gas detector is specifically designed for continuous monitoring in hazardous areas. Based on our third generation LaserGas™ Technology, the entire instrument is built into compact flameproof enclosures which makes it ideal for zone 1 locations. The LaserGas™ III OP consists of a transmitter and receiver unit that is mounted facing each other at distances up to 100 meters. The laser light is sent from the transmitter to the receiver and any changes in gas concentration along the optical path from the transmitter to the receiver are detected in real-time.

Most popular related searches
  • Gen. 3 compact LaserGas Technology
  • For operation in zone 1 (Explosion proof, Ex-d)
  • Automatic health check
  • Low power < 15 Watt
  • No need for regular replacement of parts
  • No interference from other gases
  • Factory calibrated, no zero drift
  • Suitable for SIL2

Open Path monitors are critical in emission monitoring across a wide range of industrial applications:

  • Oil and gas industry
  • Petrochemical refineries
  • Chemical plants
  • Metal industry
  • Fenceline monitoring

  • Compact high performance gas monitor for ambient long distance monitoring
  • No cross interference from other gases
  • Easy to install
  • Limited need for maintenance
  • Low cost of ownership
  • Proven and reliable

General

  • Type: Near IR Diode Laser Spectroscopy
  • IR-source: Diode laser Class1 M, eye safe
  • Detected gas: HF
  • Range: Minimum 0-5 ppm*m
  • Path lenght: 5-100 m
  • Self-test: Continuous
  • Calibration: Factory set, no field calibration necessary

Performance

  • Zero: <+/- 1% of full scale
  • Repeatability: <+/- 1% of full scale
  • Response time: 5 sec (adjustable)

Optics

  • Alignment: +/- 0.15 deg
  • Obscuration: > 90%

Output signals

  • Standard: 4-20 mA source or sink, max load impedance 500 Ohm
  • Options: Ethernet
  • Fault signals:
    • Fault 1mA
    • Beam Block 2 mA
    • Warning 3 mA

Electrical

  • Power Supply: 24V DC range 18-32V DC
  • Power consumption: < 15W

Temprature range

  • Storage temprature: -55 °C to 75 °C
  • Operating: -40 °C to 65 °C
  • Humidity (operational): 100% RH

Material

  • TU and RU: Stainless steel (ASTM 316)

Dimensions / weight

  • Footprint/weight: Ø 125mm x 250 mm/5.5 Kg (12 lbs.) per TU or RU

Maintenance

  • Visual inspection: Recommended every 6 – 12 months (no consumables needed)
  • Calibration: Check recommended every 12 months

Approvals

  • ATEX zone 1: II 2 G Ex d [op is] IIC T6 (TU/RU) II 2 D Ex tb IIIC T88 °C
  • IECEx: PENDING
  • Ingress: IP66/IP67 IEC 60529
  • SIL: Suitable for use in SIL2 systems

Optional junction box (technical data)

  • Junction box: GRP / aluminum
  • Footprint Junction box: 250 mm x 250 mm/ 2.0 Kg (4.4 lbs. per Junction Box)
  • ATEX rating: II 2 G Ex e I IC T4/T5/ T6