Endress+Hauser Group Services AG
  1. Companies
  2. Endress+Hauser Group Services AG
  3. Products
  4. iTEMP - Model TMT72 - Temperature ...

iTEMPModel TMT72 -Temperature Transmitter

SHARE

Transformation of sensor signals into stable and standardized output signals for all industries. Unsurpassed reliability, accuracy and long-term stability in critical processes across all industries. The configurable transmitter transfers converted signals from RTD and thermocouple (TC) temperature probes, as well as resistance and voltage signals using HART® communication. Diagnostics information according to NAMUR NE 107. Seamless integration into all major control and asset management systems. Integrated Bluetooth® interface for remote operation via Endress+Hauser SmartBlue App.

Most popular related searches
  • Safe operation in hazardous areas thanks to international approvals

  • Reliable operation thanks to sensor and device monitoring

  • Integrated Bluetooth® interface for the wireless display of measured values and configuration via E+H SmartBlue (app), optional

  • Diagnostics information according to NAMUR NE 107

  • Available with plug-on display TID10

  • Optimization of the measurement accuracy by sensor-transmitter matching.

  • Bluetooth®-enabled temperature transmitter with HART® communication for the conversion of various input signals into a scalable, analog 4 to 20 mA output signal

  • Improved process efficiency and increased plant uptime

  • Universal input for RTD, TC, resistance transmitters (Ω), voltage transmitters (mV)

  • Installation in terminal head form B (flat face) as per DIN EN 50446

  • Installation in cabinets with DIN rail housing

  • Optional installation in field housing even for use in Ex d applications

  • Measuring principle

    Head transmitter

  • Input

    1 x RTD, TC, Ohm, mV

  • Output

    1 x analog 4...20 mA / HART

  • Auxiliary power supply

    10…36 V DC

  • Communication

    HART-protocol

    Bluetooth® technology

  • Installation

    Terminal head form B

    Field housing

  • Accuracy

    (Pt100) <= 0,07K (digital) + 0,03% (set range)

  • Galvanic isolation

    yes

  • Certification

    ATEX II1G Ex ia IIC T6

    ATEX II3G Ex ic IIC T6 Gc

    ATEX II3D Ex tc IIIC Dc

    ATEX II3G Ex nA IIC T6

    ATEX II2G Ex ia IIC T6, II3D Ex ia IIIC Dc

    ATEX II1G Ex ia IIC T6, II3D

    ATEX II3G Ex nA IIC T6, II3D

    ATEX II2G Ex db IIC T6 Gb, II2D Ex tb IIIC Db

    CSA C/US IS, NI I / 1+2/A-D

    CSA C/US XP, NI, DIP I, II, III/1+2/A-G

    IECEx Ex d T6 Gb, Ex tb IIIC Db

    ATEX IECEx II1G Ex ia IIC T6 Ga

    ATEX IECEx II2D Ex tb IIIC Db