Tengine Innovation - Model TMS-D3100 -Multi Parameter Water Quality Analyzer
The TMS-D3100 is a multi-parameter water quality analyzer to meet the water quality monitoring needs of water treatment plants and secondary water supply systems. This product can measure parameters such as residual chlorine/chlorine dioxide, turbidity, pH, conductivity, ORP, dissolved oxygen, TDS, and temperature. Application Areas: • Water Treatment Plant • Secondary Water Supply Pump Room • Water Supply Pipeline Network • Rural Drinking WaterHighly integrated and easy to install, all sensors and display/transmission units are housed within a single enclosure.
The modular design allows flexible configurations for 4-parameter, 5-parameter, and 6-parameter setups.
The turbidity LED light source boasts a lifespan of 5 to 10 years and features light source compensation, ensuring minimal measurement drift and eliminating the need for on-site periodic calibration, making it simple to use.
The turbidity sensor employs a spiral water inlet design and is equipped with a piston-type self-cleaning function, enabling pressurized measurement without the need for manual maintenance.
The residual chlorine measurement adopts a reagent-free design, requiring no electrolyte replacement, making it pollution-free and low-maintenance.
Standard configurations include RS485 Modbus RTU output, 6 channels of 4~20mA output, and 6 relay outputs, meeting the needs of various applications.
Water consumption is as low as 0.3 tons per day, saving 80% of water usage compared to split-type devices, thereby conserving water resources.
Intelligent self-diagnosis capabilities include functions for detecting water shortage, leaks, and other faults.
Extended data storage allows for a 10-minute storage interval, capable of saving data for up to 10 years.
Measurement parameters:Residual chlorine or chlorine dioxide, turbidity, PH, temperature, ORP, conductivity, dissolved oxygen
Measuring principle:
Residual chlorine/chlorine dioxide: Microelectronic electrode method
PH/ORP: Glass electrode method
Turbidity: 90 ° scattered light method
Conductivity: Quadrupole electrode method
Temperature: Thermistor
Dissolved oxygen: fluorescence method
Residual chlorine:
Range: 0-2 mg/L and 0-5mg/L
Resolution: 0.001mg/L
Accuracy: ± 2% or ± 0.02mg/L, calculated as chlorine, whichever is greater in absolute value
Response time: ≤ 2.5min
Chlorine dioxide:
Range: 0~2mg/L
Resolution: 0.001mg/L
Accuracy: ± 5% or ± 0.02mg/L, whichever is greater in absolute value
Response time: ≤ 2.5min
Turbidity:
Range: 0~20 NTU, customizable range of 100 NTU;
Resolution: 0.001NTU
Accuracy: ± 2% reading or ± 0.02NTU, whichever is greater in absolute value;
Response time: ≤ 0.5min
pH:
Range: 0~14pH
Resolution: 0.01pH
Accuracy: ± 0.1pH;
Response time: ≤ 0.5min
Electrical conductivity:
Range: 0-10ms/cm
Resolution: 0.01us/cm
Accuracy: ± 1% or 1us/cm, whichever is greater in absolute value;
Response time: ≤ 0.5min
Temperature:
Range: -5~60 ℃
Resolution: 0.01 º C
Accuracy: ± 0.2 º C;
Response time: ≤ 0.5min
ORP:
Range: -2000mv~2000mv
Resolution: 0.3mV
Accuracy: ± 20mv;
Response time: ≤ 0.5min
dissolved oxygen:
Range: 0-20 mg/L or 0-200 air saturation
Resolution: 0.01mg/L
Accuracy: ± 2% or ± 0.15mg/L, whichever is greater in absolute value;
Response time: ≤ 1 minute
Dimensions:
47cm (width) * 68cm (height) * 28cm (thickness)
weight:
45kg (with packaging)
Power supply:
Supply voltage 220VAC ± 20%, 50Hz
The average power is 16W, and the power during automatic cleaning is 35W
Digital signals:
An RS485, Modbus RTU protocol
Application Areas:
• Water Treatment Plant
• Secondary Water Supply Pump Room
• Water Supply Pipeline Network
• Rural Drinking Water