Det-Tronics - Detector Electronics Corporation is part of Carrier
- Home
- Companies
- Det-Tronics - Detector Electronics ...
- Products
- Det-Tronics - Model GT3000 - Toxic Gas ...
Det-Tronics - Model GT3000 -Toxic Gas Detector
The Det-Tronics GT3000 line of electrochemical fixed-point toxic-gas detectors provides continuous monitoring of the atmosphere for potentially hazardous toxic gas leaks or oxygen depletion.
Most popular related searches
toxic gas detection system
toxic gas
gas detection system
toxic gas detection
hazardous area
toxicity detector
fixed toxic gas detector
fixed point gas detector
point gas detection system
gas detection
The GT3000 family currently includes sensors that detect each of the following gases (additional gases added soon):
- hydrogen sulfide (H2S)
- oxygen (O2)
- carbon monoxide (CO)
- ammonia (NH3)
- chlorine (Cl2)
- sulfur dioxide (SO2)
A complete GT3000 detector consists of a transmitter (GTX) and a sensor module (GTS). The transmitter generates a 4-20mA output signal with HART that is proportional to the concentration of the target gas and corresponds directly to 0-100% full scale output.
Although compatible with the FlexVu Universal Display, the GT3000 is approved as a stand-alone unit and supports local calibration without the FlexVu display.
- The GT3000 detectors simplify service and maintenance tasks by allowing the sensor to be changed under power without de-classification of hazardous areas and by providing easily accessible event log records via the HART communication protocol.
- Inventory costs and technician training costs stay low because the same transmitter is used for all GT3000 detectors. Commonality of design allows users to simply attach a variety of GT3000 sensors to transmitters.
- The GT3000 family of detectors is well suited for hazardous locations and has been tested by a third party to the Ingress Protection standard, achieving the IP66 rating.
- Performance approved and verified
- Electrochemical sensor cell for increased accuracy, stability, and reliability
- Highly specific response reduces the chance of false alarms resulting from the presence of other gases
- Self-contained transmitter circuitry
- Temperature compensated to ensure consistent performance over entire operating temperature range
- Suitable for outdoor applications requiring IP66 rating
- Hydrophobic filter easily replaced without opening the device or use of tools
- Hot swappable IS sensor module for live maintenance without de-classification of hazardous area
- EMI/RFI hardened
- Event and calibration logs are stored in non-volatile memory and are accessible using a UD10/UD20, HART device, or AMS software.
- Real-time clock with battery back-up
- Magnetic switch and LEDs for user interface