Ellab A/S

TrackSenseModel Pro XL -Data Logger for Double Semi Flexible High Temperature Sensor

SHARE

The Double Semi Flexible High Temperature Sensor has a temperature range of 0 to +400 °C with an accuracy of ± 0.5 °C (in range 0 to +400 °C). The sensor can be used for various application, but is ideal for high temperature applications within the pharmaceutical industry, such as depyrogenation and ovens. The high quality wireless TrackSense Pro XL data loggers consist of high resistant stainless steel and offers high-end technology that allows for stable and highly accurate measurements within different thermal processes.

Most popular related searches

The TrackSense Pro data logger series are equipped with an Interchangeable sensor option, unlocking several measuring parameters:

  • Temperature
  • Pressure
  • Conductivity
  • Relative humidity
  • CO2
  • Vacuum
  • Steam Penetration

The data loggers can easily be activated and read by the Multi reader station and combined with the Sky module for real time data via wireless communication.

  • Temperature Range of 0 to +400 °C
  • Live Data Option Available
  • Interchangeable Sensor Design

  • One logger - multiple sensor options
  • 21 CFR Part 11 Compliant
  • Real time data with the SKY module
  • User-friendly validation software
  • Usable with E-Val Pro thermocouple system
  • Sensor with this logger configuration: Double Semi Flexible High Temperature Sensor
  • Temperature Measuring Range: 0 to +400 °C (>150 °C using Thermal Barrier)
  • Measuring Principle: Electrical Resistance
  • Sensor Element: Pt1000
  • Diameter: 2 mm
  • Length: 150 – 1.000 mm
  • Position of Measuring Point from Tip: 3 mm
  • Accuracy: 0 to +400 °C: ± 0.5 °C
  • Sensor Response Time:
    • T-63%:: 1.5 Second
    • T-90%: 2.9 Seconds

Logger with this sensor configuration: Pro XL 3G

  • Operating Temperature: 0 to +400 °C (>150 °C using Thermal Barrier)
  • Operating Pressure: 0.001 mBar to 10 Bar ABS
  • House Material: 316 L Stainless Steel
  • Diameter: 25 mm
  • Length: 68.8 mm
  • Weight With Battery: 80 Grams
  • Memory Capacity: 120,000 Data Points / 60,000 Samples
  • Minimum Sample Rate: 1 Second
  • Maximum Sample Rate: 24 Hours
  • Maximum Start Delay: 14 Days
  • Intrinsically Safe: Ex II1GD Ex ia IIC T3 Ga, -55°C ≤ Tamb ≤ +105°C
  • Time Accuracy: ± 5 Seconds Per 24 Hours
  • Battery: TSP 150L Battery

Please Note: If equipment is used in ATEX environment, special conditions for safe use stated in ATEX certificates section 17 must be considered.