Trojan TrojanUV3000Model B -UV Treatment System for Small Wastewater Plants

SHARE

An operator-friendly, economical UV treatment system for small wastewater plants. The TrojanUV3000®B is a simple, yet robust system designed for small wastewater treatment plants that are looking to treat 1 – 5 MGD (158 – 789 m3/hr). The system is straightforward to use and requires minimal operator involvement thanks to its modular design and proven components.

Most popular related searches

Streamlined Installation
The TrojanUV3000B can be easily retrofitted into existing chlorine contact tanks and effluent channels, and comes pre-tested, pre-assembled and pre-wired to minimize installation costs. All components can be installed outdoors, eliminating the need for and costs of additional buildings.

Space-saving electronic lamp drivers are housed right in the modules – not in separate external cabinets – and are cooled by convection. All module wiring is pre-installed, factory-tested, and enclosed inside a waterproof frame.

Modules are lightweight and electrically separate, allowing a single module to be removed without disrupting flow or taking the system offline. Lamps are guaranteed for 12,000 hours of operation and can be replaced without tools. A UV lamp status indicator provides at-a-glance monitoring and helps determine when replacement is needed.

The TrojanUV3000B has been validated through microbial testing. Through this testing, performance data has been generated for UV dose delivery to inactivate microorganisms Escherichia coli (E. coli ) and fecal coliform.

The System Control Center (SCC) provides digital display of bank status, lamp hours, and UV intensity. Individual banks can be turned on and off automatically in response to variations in flow rate (based on a flow meter signal). This flow pacing maximizes operating efficiency by matching UV output to treatment requirements and reducing electrical consumption during periods of low flow.

  • Is your wastewater treatment plant`s flow rate 3 MGD or under? If so, the TrojanUV3000®PTP is another option you should consider. Learn more

System Characteristics: TrojanUV3000B

  • Typical Applications: 1 – 5 MGD (158 – 789 m3/hr)
  • Lamp Type: Low-pressure
  • Lamp Driver Type: Electronic; non-variable
  • Input Power Per Lamp: 87.5 Watts
  • Lamp Configuration: Horizontal, parallel to flow
  • Module Configuration: 4, 6 or 8 lamps per module
  • Bank Configuration: Up to 20 modules per bank

Channel Configurations

  • Lamp Banks in Series: Up to 3
  • Channel Options: Concrete (by others)
  • Level Control Device Options: ALC gate or fixed weir

Enclosure Ratings

  • System Monitor/Control Center: 304 stainless steel
  • Lamp Driver Enclosure: Type 6P (IP67)
  • Lamp Driver Cooling Method: Convection; no air conditioning or forced air required
  • Installation Location: Indoor or outdoor

System Monitoring & Controls

  • Controller: Monitoring and bank control
  • UV Intensity Monitoring: Optional
  • Flow Pacing: Optional
  • Inputs Required: 4-20 mA flow signal for Flow Pacing
  • Local Status Indication: Lamp Age (hours)
  • UV Intensity (mW/cm2)
  • Bank Status (on/off)
  • Low Intensity Alarm
  • Remote Alarms: UV Intensity (4-20 mA)
  • Common Alarm (discrete)
  • Location: Indoor or outdoor
  • Maximum Distance from UV Channel: 20 ft. (6 m)

Electrical Requirements

  • Power Distribution: Power Distribution Centre
  • Quantity Required: 1 PDC per bank
  • Power Input:  120V; single phase 208V,
  • 3-phase 240V; single phase