Solid State Cooling Systems
Solid State Cooling Systems - Model ThermoRack 1201 -Ultimate Rackmount Chiller
The ultimate rackmount chiller for Plasma Etch and other Semi Applications
Most popular related searches
process fluid
stainless steel pump
water flow rate
water heating
water flow rating
level sensor
environmental regulations
cooling water
coolant fluid
process water
- 1,200 watts of cooling capacity
- ±0.05°C Temperature Stability/repeatability
- Operating range from -10°C to 80°C
- Designed for very fast response
- Reduces wafer to wafer variations and eliminates first wafer effect
- Up to 80% more energy efficient than compressor-based chillers
- Uses thermoelectric technology for high reliability and reduced maintenance cost
- Simple design – only 2 moving parts
- Eliminates Freon and other harmful refrigerants to comply with new environmental regulations
- Uses less facility water and expensive coolants, such as Fluorinert or Galden
- Compact size: Up to 6 TR1201 systems fit in the space of 1 compressor chiller
- Communication interfaces available for AMAT, LAM, TEL and Hitachi systems
- Universal power – plug in and go anywhere in the world
- An excellent solution for plasma etch, plasma ash, CMP and other processes
- Auxiliary Heater available for heating above 65°C
- Ask about our trade-in offers
Operating Range: 5°C to 80°C (-10°C to 80°C with N2 option), LT Option required if operating below 0°C
Ambient Temperature: 10°C to 40°C non-condensing
Stability / Repeatability: ± 0.05°C at constant load (even near ambient)
Cooling Capacity*: ~1,200 watts @ 20°C with 20°C facility water
Heating Capacity**: ~2,000 watts @ 20°C with 20°C facility water
Coolant / Process Fluid: Fluorinert / Galden / HFE or Water/Glycol
Process Fluid Fittings: 1/2" Swagelok (316 stainless steel)
Pump: Brushless DC magnetically driven centrifugal
Flow Rate: 14-18 lpm @ 20 psig (process fluid dependent)
Tank Volume: 5.7 liter (1.5 gal) with 2 level sensors
Facility Water: 4-19 lpm (1-5 gpm) @ 10-35°C filtered, treated recirculating facility cooling water, pH 6.5 to 8.2
Facility Water Fittings: 1/2" Swagelok (316 stainless steel)
N2/CDA (N2 Option): 500 sccm -30°C dew point or lower CDA or N2, 30-60 psig (2-4 bar) for low temperature operation
Wetted Materials: Process: Aluminum, stainless steel and polymers
Facility: Sealed hard anodized aluminum and stainless steel
Facility: Sealed hard anodized aluminum and stainless steel
Size (W x D x H): 19" x 24" x 8.7" 5U (48 cm x 61 cm x 22 cm)
Weight: 70 lbs (31 kg)
Power Input: 200-240 VAC 1 phase, 50/60 Hz, 10 amp max
Circuit Breaker: 16 amp 200-250 VAC 2-pole with 30 mA GFCI
Remote EMO: External dry contact
Communications: Lam, Applied Materials, TEL, RS232, others
Alarms: Temperature, fluid level, system or component, failure (display, dry contact and machine interface)
Standards: Semi S2-0200, F47 compliant, CE
Warranty: 2 years
*Note: Cooling capacity will vary with configuration and faclity water temperature / flow rates
**Note: Heating capacity is very limited at 80°C. Contact SSCS to discuss our Auxiliary Heater.