Most popular related searches

Unique CDsystem chromatography workstation software

  • Unique CDsystem is a powerful, advanced and stable chromatographic data management system
  • CDsystem is integrates the functions of instrument control, method edit, evaluation, standard curve, report editing, user authority management, audit trial, electronic signature, network database etc
  • CDsystem meets the requirements of FDA 21 CFR, Part 11 / GLP / GMP, and meets the requirements of the pharmaceutical industry for data traceability and safety

Product Model and Technical Parameters

  • Standard configuration

Unique AutoPure Piston Pump
Unique AutoPure25

  • Piston Pump: Binary gradient biological inert infusion pump
  • Flowrate Range: 0.001-25ml/min
  • Gradient type: linear, isocratic, step gradient

Unique AutoPure100

  • Piston Pump:Binary gradient biological inert infusion pump
  • Flowrate Range: 0.001-100ml/min
  • Gradient type: linear, isocratic, step gradient

Unique AutoPure150

  • Piston Pump: Binary gradient biological inert infusion pump
  • Flowrate Range: 0.001-150ml/min
  • Gradient type: linear, isocratic, step gradient

Unique AutoPure300

  • Piston Pump:Binary gradient biological inert infusion pump
  • Flowrate Range: 0.01-300ml/min
  • Gradient type: linear, isocratic, step gradient
  • Modular design providing multiple configurations to meet special process requirements
  • High-precision double plunger infusion pump with multiple patented technologies to ensure excellent separation reproducibility
  • All parts of the whole system in contact with liquid are made of biocompatible materials, which meet the requirements of FDA, USP VI and other relevant laws and regulations
  • DAD full spectrum direct reading detector to avoid the instability and high failure rate brought by the traditional mechanical grating detector
  • The fixed wavelength detector lamp is a long-life LED lamp with a service life of more than 8000 hours, which ·reduces the maintenance cost
  • Patented ultraviolet detector flow cell, with low dead volume and low peak expansion, which improves chromatography resolution
  • High sensitivity on-line pH, conductivity and UV detector, low dead volume and low peak expansion, which improves chromatography resolution
  • Centralized automatic components such as buffer selection valve, automatic sampling valve and column position valve, which improves the automation degree of purification